• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC - SPENCER EXPECT PULMONARY OLYMPUS 25GA; ENDOBRONCHIAL ULTRASOUND TRANSBRONCHIAL ASPIRATION NEEDLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC - SPENCER EXPECT PULMONARY OLYMPUS 25GA; ENDOBRONCHIAL ULTRASOUND TRANSBRONCHIAL ASPIRATION NEEDLE Back to Search Results
Model Number M00558250
Medical Device Problem Code Bent (1059)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 01/27/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).A visual evaluation of the returned device found that the working length of the needle and sheath were kinked near the distal end of the handle and the distal section of the needle was also found to bent.Functional test was performed and the needle was able to extend and retract however, resistance was felt when the handle was actuated due to the kinked found in the device.The reported event of needle would not extend was confirmed.Due to operational and anatomical factors encountered during the procedure including the needle bent in the distal section, this condition limited the overall performance of the device causing resistance due to the friction between the needle and sheath during the handle actuation.Therefore, the most probable root cause classification for the reported failure is operational context.A dhr (device history record) review was performed and no deviation was found.A search of the complaint database confirmed that no similar complaints exist for the specified batch.
 
Event or Problem Description
It was reported to boston scientific corporation that an expect pulmonary olympus needle device was used in the airway during an endobronchial ultrasound (ebus) procedure performed on (b)(6) 2017.According to the complainant, during the procedure, the needle would not actuate during the first pass.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.The investigation found that the distal section of the needle was bent.This is now deemed an mdr reportable event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXPECT PULMONARY OLYMPUS 25GA
Common Device Name
ENDOBRONCHIAL ULTRASOUND TRANSBRONCHIAL ASPIRATION NEEDLE
Manufacturer (Section D)
BOSTON SCIENTIFIC - SPENCER
780 brookside drive
spencer IN 47460
MDR Report Key6385084
Report Number3005099803-2017-00571
Device Sequence Number501367
Product Code EOQ
UDI-Device Identifier08714729861416
UDI-Public(01)08714729861416(17)20191130(10)19934622
Combination Product (Y/N)N
Initial Reporter StateHI
Initial Reporter CountryUS
PMA/510(K) Number
K151315
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/16/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Expiration Date11/30/2019
Device Model NumberM00558250
Device Catalogue Number5825
Device Lot Number19934622
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/07/2017
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/16/2017
Initial Report FDA Received Date03/07/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-