Model Number 16402
Device Problem Device Displays Incorrect Message (2591)
Patient Problem No Information (3190)
Event Date 03/29/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
It was reported that the pump control unit error was over speeding.No other details regarding the nature of this event were provided.Diligence attempts are still ongoing in obtaining event information.
 
Event Description
An alternate device was employed.The surgical procedure was completed successfully.There was no delay, no blood loss, nor adverse consequences to the patient.Per clinical review: this occurred during set-up.An overspeed error was observed with this pump serving as a sucker.No patient exposure as it was during set-up and the pump was not used for the procedure.
 
Manufacturer Narrative
(b)(4).The field service representative (fsr) verified that the roller pump displayed over speed 1 error.He found that the pump driver printed circuit board assembly (pcba) was the source of the problem.The pump driver pcba was replaced.The unit operates to the manufacturer's specifications.The suspect part was returned to the manufacturer for further evaluation.
 
Manufacturer Narrative
The reported complaint was confirmed.During laboratory analysis, the product surveillance technician (pst) installed the printed circuit board (pcb) onto a lab 8k pump test fixture.The pst operated the test fixture for 48 hours with no overspeed occurring.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SARNS 8000 UNIVERSAL ROLLER PUMP
Type of Device
PUMP, BLOOD, CARDIOPULMONARY BYPASS, ROLLER TYPE ¿ SARNS 8000 UNIVERSAL ROLLER
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORP.
6200 jackson road
ann arbor MI 48103
Manufacturer Contact
katie hoyt
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key6540096
MDR Text Key74419334
Report Number1828100-2017-00211
Device Sequence Number1
Product Code DWB
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K953901
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Reporter Occupation Other
Type of Report Initial,Followup,Followup,Followup,Followup
Report Date 09/06/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/03/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number16402
Device Catalogue Number16402
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/04/2017
Is the Reporter a Health Professional? No
Date Manufacturer Received08/18/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/25/2004
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-