| Model Number |
RIBLOC U PLU |
| Medical Device Problem Codes |
Break (1069); Insufficient Device Problem Information (3190); Missing Value Reason (3192)
|
| Health Effect - Clinical Codes |
Discomfort (2330); Patient Problem/Medical Problem (2688); No Information (3190); Missing Value Reason (3192)
|
| Date of Event |
04/07/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Plate removal cause unknown.Surgeon removed plate from lower rib (9 or 10) but had to leave part of the plate in place because he could not remove it completely.Surgeon broke the plate in a few pieces and was able to remove most of it.Posterior part of the plate remained intact.It was reported that the fracture had healed and replating was not necessary.Plates being returned for investigation.
|
| |
|
Event or Problem Description
|
|
Plate removal cause unknown.Surgeon removed plate from lower rib (9 or 10) but had to leave part of the plate in place because he could not remove it completely.Surgeon broke the plate in a few pieces and was able to remove most of it.Posterior part of the plate remained intact.It was reported that the fracture had healed and replating was not necessary.Plates being returned for investigation.Event update: the surgeon reported the following: the patient is a (b)(6)gentleman 6 foot (b)(6) in good shape fairly muscular he was involved in a motorcycle accident around two years ago and sustained multiple right sided rib fractures that were treated conservatively he presented to me several months after the accident (almost a year ) with pain form a displaced nonunion for the 8th of rib posterior laterally.I took him to the operating room (or) where i was able to reduce the fracture and re approximate the rib and placed the rib lock plate (i believe tom has supplied you with detail of size and screws.He had an excellent post op result with resolution of pain and was able to return back to normal daily activities.He presented back to us about 2 months ago with a rather sudden onset of recurrence of pain in the area and xrays confirmed a fracture in the plate.Other than normal daily activities he did not recall any specific trauma or incident i suspect that with the length of the plate across the bridged area that there may have been just enough flexing to result in weakening of that area.I took him back to the or explored him and removed all of the plate with the exception of one of the locking talons which was embedded and fractured off in the dissection no attempt was made to dissect it out further as it would have involved violating the pleural space.The plate was buried well under the latissimus muscle also making exposure cumbersome, as well as the reaction around the plate itself.We used the instrumentation to extract the screws and lift the plate off the bone, but with bone callous formation around the locking talons they were difficult to loosen the rib appeared to remain well approximated with good bone callous and was sufficiently healed and not felt to need a new plate placed i have seen him in post op follow up and he again is recovering well with good resolution of pain.The plate was returned in a condition with made analysis not possible.
|
| |
|
Search Alerts/Recalls
|