| Catalog Number |
06D19-68 |
| Medical Device Problem Code |
False Negative Result (1225)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
10/10/2016
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
An evaluation is in-process.A follow-up report will be submitted when the evaluation is complete.
|
| |
|
Event or Problem Description
|
|
The customer reported a donor unit that was collected on (b)(6) 2016 generated a false nonreactive (0.61 s/co) abbott prism hbsag result.The customer indicated the donor unit generated ultrio nat positive (16.8 unit of measure not provided).When separated out for individual testing, (b)(6) were negative and (b)(6) was (b)(6) (23.87 unit of measure not provided).The customer further indicated the nonreactive results were considered to be from the window phase of detection by prism and the blood unit was frozen for potential commercial resale.The donor unit was not transfused.
|
| |
|
Additional Manufacturer Narrative
|
|
Ticket searches for the likely cause lot identified normal activity; no additional tickets for sensitivity were found.A review of the device history record for the likely cause lot did not reveal any issues related to the customer's observation.Review of the cber release panel testing for the likely cause lot was performed; all testing met specifications.Additionally, the tracking and trending review for the product determined that there were no adverse or non-statistical trends identified.Further, a review of all tickets related to patient results for the assay since 01may2016 determined that this was the only ticket identified for sensitivity.Label reviews were also performed and found to adequately address the customer's issue.Since the likely cause reagent lot expired prior to the receipt of the complaint testing could not be performed.Therefore, a review of the prism field data was performed to assess performance of the abbott prism (b)(6) lot 62084m500.This review included a comparison of initial and repeat (b)(6) rates for the lot to the package insert claims as well as a comparison to other masterlots within a similar timeframe.Additionally, positive and negative control data were compared to package insert specifications and other lots within a similar timeframe.The outcome of this review determined that the reagent lot to be within package insert claims and specifications as well as performing comparable to other lots within a similar timeframe.The fda-licensed hbv nat can detect evidence of infection at an earlier stage than is possible using approved (b)(6) tests.A review of all data associated with this complaint indicates these results are consistent with a "window donor" in which the onset of infection precedes the detectability of the abbott prism (b)(6), however the evidence of infection is detectable by fda-licensed (b)(6) nat testing.Based on the results of this investigation the prism (b)(6) assay is performing acceptably and no deficiency was identified.
|
| |
|
Search Alerts/Recalls
|