• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC - MAPLE GROVE APEX¿; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC - MAPLE GROVE APEX¿; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number H7493895915300
Medical Device Problem Codes Break (1069); Device Damaged Prior to Use (2284)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 04/18/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Device evaluated by mfr: the device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.(b)(4).
 
Event or Problem Description
It was reported that shaft break occurred.During preparation of a 3.00mm x 15mm apex¿ balloon catheter, when the stylet was removed from the tip of the balloon, it was noted that the shaft separated at the proximal monorail port.The device was not used inside the patient and the procedure was completed with another 3.00mm x 15mm apex balloon catheter.No patient complications were reported and the patient¿s status was fine.
 
Additional Manufacturer Narrative
Device evaluated by mfr: returned product consisted of the proximal portion of the apex balloon catheter.The distal shafts after the exit notch, the balloon, markerbands, and tip were not returned for analysis.The hypotube and portion of the shaft that was returned for analysis was microscopically examined.The distal shaft was stretched 2.5mm ¿ 7.5mm distal of the exit notch and separated 7.5mm distal of the exit notch.The separated end of the shaft appeared to be jagged and damaged, which indicates that the separation was due to tensile overload.Inspection of the remainder of the device, apart from the observed damage, revealed no other damage or irregularities.No other issues were identified during the product analysis.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The most probable root cause is considered handling damage as the event occurred without direct patient contact.(b)(4).
 
Event or Problem Description
It was reported that shaft break occurred.During preparation of a 3.00mm x 15mm apex¿ balloon catheter, when the stylet was removed from the tip of the balloon, it was noted that the shaft separated at the proximal monorail port.The device was not used inside the patient and the procedure was completed with another 3.00mm x 15mm apex balloon catheter.No patient complications were reported and the patient¿s status was fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
APEX¿
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
MDR Report Key6559404
Report Number2134265-2017-04488
Device Sequence Number1134647
Product Code LOX
UDI-Device Identifier08714729475637
UDI-Public(01)08714729475637(17)20200229(10)20293293
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
P860019
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/20/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/29/2020
Device Model NumberH7493895915300
Device Catalogue Number38959-1530
Device Lot Number20293293
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/12/2017
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 04/20/2017
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date05/10/2017
Supplement Report FDA Received Date06/05/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-