MAUDE Adverse Event Report: ARROW INTERNATIONAL INC. EPIDURAL CATHETERIZATION KIT; ANESTHESIA CONDUCTION KIT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL INC. EPIDURAL CATHETERIZATION KIT; ANESTHESIA CONDUCTION KIT Back to Search Results
Catalog Number FH-05500-J
Device Problem Infusion or Flow Problem (2964)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 05/01/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been returned for investigation at this time.Teleflex will continue to monitor and trend related events.
 
Event Description
A flashing test was performed prior to insertion of the catheter and no problem was confirmed at that time.However, after placement of the catheter, the medical agent did not go through the inserted catheter so the catheter was replaced by a new one.There was no patient injury.
 
Manufacturer Narrative
(b)(4).A device history record review was performed on the epidural catheter with no relevant findings.The customer reported the catheter is blocked.The customer returned one snaplock adapter with clip, one flat filter, and one epidural catheter.The snaplock adapter, flat filter, and catheter were received connected together (reference attached files (b)(4)).The returned components were visually examined with and without magnification.Visual examination of the returned snaplock adapter revealed the snaplock adapter appears typical with no observed defects or anomalies.Visual examination of the returned flat filter revealed the filter appears typical with no observed defects or anomalies.Visual examination of the returned catheter revealed the catheter appears used.Biological material can be seen within the inner coils of the catheter and adhesive material can be seen on the outer extrusion of the catheter.No other defects or anomalies were observed.A manual flow test was performed using the returned components.A 20ml lab inventory syringe was connected to the returned flat filter, the returned other remarks: snaplock adapter, and returned catheter.Using hand pressure, the water was injected.Water could be seen immediately exiting the distal end of the catheter.No blockages were found.The reported complaint of the catheter was blocked could not be confirmed based on the sample received.A device history record review was performed on the epidural catheter with no evidence to suggest a manufacturing related issue.The returned components passed a functional flow test.There were no functional issues found with the returned sample.
 
Event Description
A flashing test was performed prior to insertion of the catheter and no problem was confirmed at that time.However, after placement of the catheter, the medical agent did not go through the inserted catheter so the catheter was replaced by a new one.There was no patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EPIDURAL CATHETERIZATION KIT
Type of Device
ANESTHESIA CONDUCTION KIT
Manufacturer (Section D)
ARROW INTERNATIONAL INC.
reading PA
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
jasmine brown
3015 carrington mill blvd
morrisville, NC 27560
9193614124
MDR Report Key6576652
MDR Text Key75506524
Report Number3006425876-2017-00161
Device Sequence Number1
Product Code CAZ
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/08/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/18/2017
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date04/30/2018
Device Catalogue NumberFH-05500-J
Device Lot Number71F16F0672
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/16/2017
Is the Reporter a Health Professional? Yes
Date Manufacturer Received06/28/2017
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/10/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-