MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 PROXIS¿ URETERAL ACCESS SHEATH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 PROXIS¿ URETERAL ACCESS SHEATH Back to Search Results
Model Number 231035
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event or Problem Description
It was reported that the ureteral access sheath shaved off part of the scope casing.There were allegedly no pieces remaining in the patients body.
 
Additional Manufacturer Narrative
Received 1 used ureteral access sheath with the original unit packaging.The reported event was not confirmed.Per the visual inspection, there was no visible damage on the outside of the sheath.After removing the dilator from the sheath, the dilator was inspected for visual damage and none was found.The dilator was successfully inserted and retracted into the sheath with no resistance observed.Under 20x magnification, the inside of the sheath hub was examined and no defects were found.Additionally, the outside of the dilator was examined under the same magnification and no issues were noted.Upon examination of the sheath distal tip, it was noted to have a slight ovality.There is no way of knowing how the slight ovality of the distal tip occurred.Additionally, the spring and the marker band were still secured under the teflon liner.A light was shone into both ends of the sheath and no issues were noted.Nothing was noted on the sheath or dilator that would damage the scope, nor was there any evidence found where the sheath or dilator was damaged by the scope.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use state the following: "description: the proxis¿ ureteral access sheath is a two component ureteral dilation system which contains a single lumen for injection of fluids as well as passage of endoscopes and related instruments.The packaged product includes the following items: 1 - hydrophilic-coated dilator with female luer connector.1 - hydrophilic-coated sheath with hub.Indications for use: the proxis¿ ureteral access sheath is indicated for use in endoscopic urology procedures where ureteral dilation andureteral access is desired for injection of fluids and insertion and removal of endoscopes and related instruments.Contraindications: patients who are contraindicated for retrograde urological procedures.Patients who are contraindicated for antegrade urologic procedures, including but not limited to patients with blood clotting anomalies due to coagulopathies or pharmacological anticogagulations.Patients who have the presence of tight strictures which would limit use of the device.Patients who have the presence of large obstructing distal ureteral calculi.Warning: for single use only.Do not reuse, reprocess or resterilize.Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure, which in turn, may result inpatient injury, illness or death.Reuse reprocessing or re-sterilization may also create a risk of contamination of the device and/or cause patient infection or crossinfection, including, but not limited to, the transmission of infectious disease(s) from one patient to another.Contamination of the device may lead to injury, illness or death of the patient.Do not use if sterile barrier is damaged.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practices and with applicable laws and regulations.Caution: federal (u.S.A.) law restricts this device to sale by or on the order of a physician.Precautions: the recommendations given are meant to serve only as a basic guide to the utilization of this access sheath.The ureteral access sheath should not be used without comprehensive knowledge of the indications, techniques and risks of the procedure.To minimize resistance during advancement, ensure the hydrophilic coating on the dilator and sheath is activated with saline or sterile water prior to placement.Do not advance sheath without the dilator in place as this could lead to trauma or injury to patient.Do not bend the device prior to placement as this could damage the integrity of the device and result in patient injury.Do not advance or withdraw device if any resistance is encountered during placement or removal without determining cause and taking action.Adverse events: potential adverse events associated with the use of the transurethral access device include, but are not limited to: mucosal irritation, inflammation and edema, urethral strictures, acute bleeding or hemorrhage, urethral, bladder, or ureteral perforation, other injury to the urinary tract.Directions for use: activate the hydrophilic coating by placing the dilator and sheath components into saline or sterile water.Place an 0.035" (0.889mm) or 0.038" (0.965mm) guidewire into the ureter using standard endourology techniques.Ensure the dilator lock is securely engaged with sheath hub prior to insertion.Insert the guidewire into the tapered end of the dilator/sheath assembly and gradually advance the assembly into the ureter.Note: placement of the assembly can be verified using fluoroscopy or radiographic means.While maintaining sheath position, disengage the dilator lock from the sheath hub to gently remove the dilator.Do not advance sheath without the dilator in place.Note: suture holes are provided on sheath hub for securing externally, if desired.An endoscope and/or related instruments can now be used through the ureteral sheath as needed.If desired, irrigation can be applied using the luer connector on the dilator.Upon completion of the access procedure, gently withdraw the device.Discard the device in accordance with hospital procedures and with applicable laws and regulations.For urological use only manufactured and packaged in u.S.A".(b)(4).
 
Event or Problem Description
It was reported that the ureteral access sheath shaved off part of the scope casing.There were allegedly no pieces remaining in the patients body.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PROXIS¿ URETERAL ACCESS SHEATH
Common Device Name
URETERAL ACCESS SHEATH
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key6595339
Report Number1018233-2017-02738
Device Sequence Number978673
Product Code FED
UDI-Device Identifier00801741101687
UDI-Public(01)00801741101687(10)BMAYFM48
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
K160861
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 11/01/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/23/2019
Device Model Number231035
Device Catalogue Number231035
Device Lot NumberBMAYFM48
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/16/2017
Initial Date Received by Manufacturer 05/01/2017
Supplement Date Received by Manufacturer10/25/2017
Initial Report FDA Received Date05/26/2017
Supplement Report FDA Received Date11/01/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-