Catalog Number 67025690B
Medical Device Problem Codes Split (2537); Physical Resistance (2578)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 05/04/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The event was initially reported on 5/8/2017; however, the event did not meet mdr criteria until 5/30/2017 when it was reported that the catheter was cracked/split.The device was returned for analysis; however, analysis has not yet begun.Additional information will be submitted within 30 days of receipt.
 
Event or Problem Description
As reported by a healthcare professional an envoy catheter (67025690b/ 17641208) would not advance up the cordis sheath, and when it could advance it was stiff and caused the envoy to break (cracked/split) at the distal tip.The same issue occurred 2 days running (additional complaint added).This hospital has used the same setup including the catheter and sheath and has had this issue occur a few times in the last calendar year; however, all complaints were reported to the manufacturer.The device was used as per the ifu, and a flush had been maintained.It was reported that the catheter and sheath was available for analysis.
 
Additional Manufacturer Narrative
As reported by a healthcare professional, an envoy catheter (67025690b/17641208) would not advance up the cordis sheath, and when it could advance, it was stiff and caused the envoy to break (cracked/split) at the distal tip.The device was used as per the ifu, and a flush had been maintained.It was reported that the catheter and sheath was available for analysis.A non-sterile envoy 6f, xb mpc was received inside of an unknown pouch inside of a plastic bag.No damages were noted on hub of the envoy.The envoy body was inspected and it was found kinked at 9.2, 18.2, 32.5, 45.8,54 59.5 and 89 cm from the proximal end of hub.No damages were noted on brite tip zone.The id and od from the envoy were measured and were found within specification.The functional analysis was performed.The envoy received was flushed using a lab sample syringe.The water came out from the distal end of the device.A 0.038¿ guide lab sample was introduced into the envoy and it advanced smoothly until to the envoy distal tip and resistance was found when the guidewire was passed through the kinked sections found on the catheter body.The envoy was introduced into the cordis cannula lab sample and it advance until the cannula distal tip end and resistance was felt in the brite tip fuse area.However, it passed totally through the brite tip fuse area of the cannula lab sample.A review of the manufacturing documentation associated with this lot 17641208 presented no issues during the manufacturing or inspection process that can be related to the reported complaint.The distal tip damage¿ was not confirmed.The difficulty passing the catheter through the introducer sheath was also not confirmed; however, there was resistance at the brite tip fusion area.The damages found on the received device were apparently caused by applying excessive force on it, but it could not be conclusively determined.These defects could not be related to the manufacturing process and procedural factors appear to have contributed to have this damage.Additionally, inspections are in place that prevents this kind of failure from leaving the facility neither the analysis nor the dhr suggest that the failure reported by the costumer could be related to the manufacturing process; therefore, no corrective action will be taken at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENVOY 6F GUIDING CATHETERS
Common Device Name
PERCUTANEOUS CATHETER
Manufacturer (Section D)
CODMAN AND SHURTLEFF, INC
325 paramount dr
raynham MA
MDR Report Key6644869
Report Number3008264254-2017-00082
Device Sequence Number13723843
Product Code DQY
UDI-Device Identifier10886704031727
UDI-Public(01)10886704031727(17)191231(10)17641208
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
K000715
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 05/08/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/31/2019
Device Catalogue Number67025690B
Device Lot Number17641208
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/30/2017
Type of Report(Section G)FDA Requested
Initial Date Received by Manufacturer 05/30/2017
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date06/15/2017
Supplement Report FDA Received Date06/26/2017
Patient Sequence Number1
-
-