• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PS FEM COMPONENT, CEMENTED; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, C

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PS FEM COMPONENT, CEMENTED; PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, C Back to Search Results
Catalog Number 5515-F-501
Medical Device Problem Code Packaging Problem (3007)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Date of Event 05/25/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A supplemental report will be submitted upon completion of the investigation.
 
Event or Problem Description
The customer reported that they opened a triathlon femur (5515-f-501 / bep2d) and the inner plastic was broken so they could not use it.
 
Additional Manufacturer Narrative
An event regarding packaging damage involving a triathlon femoral component was reported.The event was confirmed through visual inspection.One unit carton without its shrink wrap was returned for evaluation.There is a compression line visible along the opening end of the unit carton.The outer blister was returned cracked and damaged with one side flange partially removed from the outer blister.For the purpose of this investigation the tyvek lid was removed from the outer blister.There is evidence of a good seal on the outer blister.The inner blister was returned inside the outer blister with its tyvek lid still intact.For the purpose of this investigation the tyvek lid was removed from the inner blister.There is evidence of a good seal on the inner blister.The returned device appears unremarkable.Not performed as the event is related to a packaging issue and no adverse consequences to the patient were reported.Indicated all devices were manufactured and accepted into final stock with no reported discrepancies.There have been no other similar events for the lot referenced.Based on the visual inspection of the returned packaging it appears that this component packaging was subjected to excessive/inappropriate handling whereby the carton may have been compressed and/or dropped from a height causing damage to the unit carton.No further investigation for this event is possible at this time.
 
Event or Problem Description
The customer reported that they opened a triathlon femur (5515-f-501/bep2d) and the inner plastic was broken so they could not use it.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIATHLON PS FEM COMPONENT, CEMENTED
Common Device Name
PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, C
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
MDR Report Key6661442
Report Number0002249697-2017-01976
Device Sequence Number16154895
Product Code MBH
UDI-Device Identifier07613327050394
UDI-Public07613327050394
Combination Product (Y/N)N
Initial Reporter CountryGB
PMA/510(K) Number
K141056
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,other
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 09/18/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/08/2021
Device Catalogue Number5515-F-501
Device Lot NumberBEP2D
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/18/2017
Initial Date Received by Manufacturer 05/25/2017
Supplement Date Received by Manufacturer08/23/2017
Initial Report FDA Received Date06/22/2017
Supplement Report FDA Received Date09/18/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-