MEDTRONIC NEUROSURGERY STRATA II SHUNT ASSEMBLY, REGULAR, WITH BIOGLIDE; SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS Back to Search Results
Catalog Number 27819
Medical Device Problem Code Device Operates Differently Than Expected (2913)
Health Effect - Clinical Code Therapeutic Response, Decreased (2271)
Date of Event 02/12/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported to medtronic neurosurgery that after several regulatory pressures, the shunt effect was still not obvious, and the patient's condition did not decrease.According to the report, the patient was relieved when the valve was replaced, and the doctor suspected a valve failure.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
The returned valve was patent.The valve met the requirements for siphon, reflux, pressure-flow, and pre-implantation testing.There was proteinaceous debris observed within the interior and exterior of the valve.Debris within the valve may hold pressure-flow controlling mechanisms open resulting in fluid reflux.The instructions for use (ifu) that accompany the device caution that ¿shunt obstruction may occur in any of the components of the shunt system.The system may become occluded internally due to tissue fragments, blood clots, tumor cell aggregates, bacterial colonization, or other debris.¿ the returned valve did not meet the requirements for leak testing due to a tear observed in the top of the delta chamber.It is unknown how or when this damage occurred.The ifu caution that ¿care should be taken in handling the valves as silicone has a low cut and tear resistance.¿ the ifu also caution that ¿improper use of instruments in the handling or implantation of shunt products may result in the cutting, slitting, or crushing of components.¿ a review of the manufacturing records showed no anomalies.All valves are 100% tested at the time of manufacture.Approximately 89 cm of the catheter was returned.The returned catheter was patent and met the requirements for leak testing.Proteinaceous debris was noted in the interior and exterior of the catheter.The instructions for use that accompany the device caution that ¿shunt obstruction may occur in any of the components of the shunt system.The system may become occluded internally due to tissue fragments, blood clots, tumor cell aggregates, bacterial colonization, or other debris.¿ a review of the manufacturing records showed no anomalies.All catheters are 100% inspected at the time of manufacture.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Additional information received reported the doctor adjusted the setting four times, from 2.0 to 1.5 to 1.0 to 0.5, with an interval of two days between adjustments.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STRATA II SHUNT ASSEMBLY, REGULAR, WITH BIOGLIDE
Common Device Name
SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS
Manufacturer (Section D)
MEDTRONIC NEUROSURGERY
125 cremona drive
goleta CA 93117
MDR Report Key6664086
Report Number2021898-2017-00344
Device Sequence Number19347830
Product Code JXG
UDI-Device Identifier00643169010499
UDI-Public00643169010499
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K042465
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2017
Reporter Type Manufacturer
Report Source foreign,health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 10/10/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/30/2017
Device Catalogue Number27819
Device Lot NumberD61355
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/07/2017
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/25/2017
Supplement Date Received by Manufacturer07/10/2017
07/10/2017
09/18/2017
Initial Report FDA Received Date06/23/2017
Supplement Report FDA Received Date08/08/2017
09/07/2017
10/10/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age54 YR
Patient Weight54
-
-