MEDTRONIC NEUROSURGERY DELTA SHUNT ASSEMBLY, SMALL; SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS Back to Search Results
Catalog Number 46813
Medical Device Problem Code Occlusion Within Device (1423)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 06/12/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The product was unavailable for return.Therefore an evaluation of the device performance was not possible.A review of the manufacturing records showed no anomalies.All valves are 100% tested at the time of manufacture.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported to medtronic neurosurgery that the device was tested intra-operatively for flow.According to the report, during the process, it was found to be preventing any flow of fluid through the valve.Reportedly, a new device was used which when tested, it demonstrated normal flow.
 
Additional Manufacturer Narrative
The returned valve was patent.Therefore the conditions of the complaint could not be duplicated by laboratory personnel.The valve met the requirements for siphon, reflux, pressure-flow, preimplantation, and leak testing.There was proteinaceous debris observed within the interior of the valve.Debris within the valve may hold pressure-flow controlling mechanisms open affecting the flow of fluid through the valve.The instructions for use (ifu) that accompany the device caution that ¿shunt obstruction may occur in any of the components of the shunt system.The system may become occluded internally due to tissue fragments, blood clots, tumor cell aggregates, bacterial colonization, or other debris.¿ a review of the manufacturing records showed no anomalies.All valves are 100% tested at the time of manufacture.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DELTA SHUNT ASSEMBLY, SMALL
Common Device Name
SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS
Manufacturer (Section D)
MEDTRONIC NEUROSURGERY
125 cremona drive
goleta CA 93117
MDR Report Key6696934
Report Number2021898-2017-00364
Device Sequence Number1761291
Product Code JXG
UDI-Device Identifier00643169472297
UDI-Public00643169472297
Combination Product (Y/N)N
Initial Reporter CountryNZ
PMA/510(K) Number
K902783
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/12/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2021
Device Catalogue Number46813
Device Lot NumberE12731
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/07/2017
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/12/2017
Supplement Date Received by Manufacturer08/08/2017
Initial Report FDA Received Date07/10/2017
Supplement Report FDA Received Date08/24/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-