• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC SALIVARY STONE EXTRACTOR BASKET SSEB; GCJ LAPAROSCOPE, GENERAL & PLASTIC SURGERY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC SALIVARY STONE EXTRACTOR BASKET SSEB; GCJ LAPAROSCOPE, GENERAL & PLASTIC SURGERY Back to Search Results
Model Number N/A
Medical Device Problem Codes Device Operates Differently Than Expected (2913); Human Factors Issue (2948); Material Deformation (2976)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The event is currently under investigation.A follow-up report will be submitted upon receipt of additional information or completion of the investigation.
 
Event or Problem Description
It was reported that the physician was performing a sialoendoscopy procedure on a patient by using the ncircle salivary stone extractor basket (sseb).The physician attempted to retrieve 1 cm stone from wharton¿s duct.After several attempts, the physician observed that the basket became mangled and no longer could hold its original shape.The procedure was completed by opening a new basket.The customer further stated that they were trying to remove a large stone and there is a possibility that while retrieving the stone the operator may have applied excessive strength on the basket which may have caused this issue.No unintended section of the device remained inside the patient¿s body.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
 
Additional Manufacturer Narrative
Investigation summary: a review of the functional test, complaint history, device history record, quality control and a visual inspection of the returned device were conducted during the investigation.One device was returned for investigation.The returned device was found to be damaged.The device was returned with the udh handle partially open and the basket formation partially open; the basket formation extends the end of the basket sheath 5 mm.There are multiple kinks throughout the basket sheath.A functional test was performed and the udh handle actuates the basket formation to the open and closed positions.A visual examination noted the basket formation appears flat; the basket wires knot has pulled apart.The collet knob is tight and secure.The mlla (male luer lock adaptor) is finger tight.Additionally, a document based investigation evaluation was performed.There was no evidence to suggest the product was not made to specifications.A review of the device history record found no non-conformances associated with the complaint device lot number.It should be noted there were no other reported complaints for this lot number.Based on the information provided, the examination of the returned product, and the results of our investigation, a definitive root cause could not be determined.The most likely cause for the observed damage was "operative vigor" during use of the device on a massive stone.The quality engineering risk assessment for this failure mode was reviewed and it was determined that no additional risk mitigating activity is required at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SALIVARY STONE EXTRACTOR BASKET SSEB
Common Device Name
GCJ LAPAROSCOPE, GENERAL & PLASTIC SURGERY
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key6728479
Report Number1820334-2017-01806
Device Sequence Number13763840
Product Code GCJ
UDI-Device Identifier00827002237971
UDI-Public(01)00827002237971(17)200125(10)7622620
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K120468
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/17/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue NumberSSEB-1.5-115-10
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 06/23/2017
Supplement Date Received by Manufacturer01/16/2018
Initial Report FDA Received Date07/20/2017
Supplement Report FDA Received Date01/17/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-