BOSTON SCIENTIFIC - SPENCER EXPECT PULMONARY OLYMPUS 25GA; ENDOBRONCHIAL ULTRASOUND TRANSBRONCHIAL ASPIRATION NEEDLE Back to Search Results
Model Number M00558250
Medical Device Problem Code Bent (1059)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Visual evaluation revealed that the needle and sheath was kinked near the handle.In addition the distal end of the needle was bent.Functional analysis was performed and the knobs could be tightened and loosened without any issue.The complaint was not confirmed.Most likely, the way in which the device was handled during unpacking could have caused the device to kinked near the handle and distal section. therefore, the most probable root cause classification for the reported failure is handling damage.A review of the device history record (dhr) was performed and no deviations were found.A search of the complaint database confirmed that no similar complaints exist for the specified batch.
 
Event or Problem Description
It was reported to boston scientific corporation that an expect pulmonary olympus was used in the lungs during an endobronchial ultrasound (ebus) procedure.According to the complainant, during unpacking the physician was unable to adjust the sheath.The procedure was completed with another expect pulmonary olympus.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.This event has been deemed a reportable event based on the investigation results.Needle distal tip bent.
 
Additional Manufacturer Narrative
Date of report updated.
 
Event or Problem Description
It was reported to boston scientific corporation that an expect pulmonary olympus was used in the lungs during an endobronchial ultrasound (ebus) procedure.According to the complainant, during unpacking the physician was unable to adjust the sheath.The procedure was completed with another expect pulmonary olympus.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.This event has been deemed a reportable event based on the investigation results.Needle distal tip bent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXPECT PULMONARY OLYMPUS 25GA
Common Device Name
ENDOBRONCHIAL ULTRASOUND TRANSBRONCHIAL ASPIRATION NEEDLE
Manufacturer (Section D)
BOSTON SCIENTIFIC - SPENCER
780 brookside drive
spencer IN 47460
MDR Report Key6744472
Report Number3005099803-2017-02071
Device Sequence Number19052980
Product Code EOQ
UDI-Device Identifier08714729861416
UDI-Public(01)08714729861416(17)20200430(10)20519864
Combination Product (Y/N)N
Initial Reporter StateIN
Initial Reporter CountryUS
PMA/510(K) Number
K151315
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/03/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/30/2020
Device Model NumberM00558250
Device Catalogue Number5825
Device Lot Number20519864
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/16/2017
Initial Date Received by Manufacturer 07/03/2017
Supplement Date Received by Manufacturer07/25/2017
Initial Report FDA Received Date07/26/2017
Supplement Report FDA Received Date08/16/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-