| Catalog Number |
AUBS-5-4 |
| Medical Device Problem Code |
Burst Container or Vessel (1074)
|
| Health Effect - Clinical Code |
Extravasation (1842)
|
| Date of Event |
06/26/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).The event is currently under investigation.A supplemental report will be provided upon conclusion.
|
| |
|
Event or Problem Description
|
|
The patient was having a ureteroscopy for renal stone removal.The customer elected to dilate the distal ureter of the patient with a balloon and a g32837-aubs-5-4 ascend® aq® ureteral balloon catheter was used.When the balloon was inflated up to 14 atm, the balloon burst and the contrast went out/flushed up the ureter.They shot additional contrast through the ureter and it showed no extravasation.They exchanged for a g32834-aubs-4-4 ascend® aq® ureteral balloon catheter, this one ruptured at 16 atm of pressure and is reported under report number 1820334-2017-01805.It is unknown what type of medium was used to inflate the balloon.At this time, there was obvious extravasation and a stent was put in to let the ureter heal.The patient will require an additional ureteroscopy / renal stone removal after the ureter heals.
|
| |
|
Additional Manufacturer Narrative
|
|
A review of complaint history, device history record, instructions for use (ifu), specification and quality control data was conducted during the investigation.The complaint device was not returned; therefore, device failure analysis and physical examination of the device used in this case could not be performed.A review of production and quality documentation did not observe any specific issues with current manufacturing or quality controls that may have contributed to this incident.The device is shipped with the ifu which states, "warning: do not over inflate.Using excessive pressure to inflate the balloon on this device can cause the balloon to rupture." a review of the device history record found one other non-conformances associated with the complaint device lot number.A review of complaint history found no other complaints associated with the complaint device lot number.Based on the provided information, no product returned and the investigation, a definitive root cause cannot be established or reported at this time.We will notify the appropriate personnel and continue to monitor for similar complaints.Per the quality engineering risk assessment no further action is required.
|
| |
|
Search Alerts/Recalls
|