Model Number 36304
Health Effect - Clinical Code Injury (2348)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event or Problem Description
It was reported that the sheaths were too sticky and difficult to remove.The patient reported on one occasion to had removed skin off their penis, resulting in an open wound approximately 15 mm x 8 mm, which resolved after 8 days.The patient did not seek medical intervention for the wound, but kept it clean.On another occasion, the patient had to cut the sheath off and a portion remained on the penis, as it was unable to be removed until a few days later.
 
Additional Manufacturer Narrative
Received 5 mec lot samples.The reported event was unconfirmed since the sample met specification.The samples were visually inspected for holes or damage on the package, legibility of printed numbers and letters, expiration date, correct impression, print color, missing parts of printing, position of printing, damaged component, foreign matter.The catheters unrolled without difficulty.The acceptable peel strength must be in a range from 0.60 to 2.10lbf for a mec std and sample results were: sample 1: 1.15 lbf, sample 2: 1.10 lbf, sample 3: 1.12 lbf, sample 4: 1.15 lbf, sample 5: 1.21 lbf.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use state the following: "description/indication the self-adhering male external catheter is designed for the management of male urinary incontinence.Contraindication do not use on irritated or compromised skin.Precaution do not use if allergic reaction occurs.For good hygiene, change catheter daily.Use of a single device for longer periods than 24 hours may increase the risk of complications.Directions: to apply wash penis with mild soap and warm water.Dry thoroughly.Trim pubic hair if necessary.Open package at perforation.To remove plastic insert, squeeze catheter at the top of the white cone and pull to release.Unroll self-adhering catheter over penis.Gently squeeze the catheter to properly seal adhesive to the skin.Connect to collection bag.Important: wear time may be significantly reduced if adhesive is not properly sealed to the skin.Directions: to remove gently roll catheter off the penis.Note: if necessary, apply a warm wet compress (such as a wet washcloth) around the catheter to help loosen the adhesive." (b)(4).
 
Event or Problem Description
It was reported that the sheaths were too sticky and difficult to remove.The patient reported on one occasion to had removed skin off their penis, resulting in an open wound approximately 15 mm x 8 mm, which resolved after 8 days.The patient did not seek medical intervention for the wound, but kept it clean.On another occasion, the patient had to cut the sheath off and a portion remained on the penis, as it was unable to be removed until a few days later.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROCHESTER MEC WIDEBAND L 30BX
Common Device Name
MEC
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
parque industrial aeropuerto
covington GA 30014
MDR Report Key6758646
Report Number1018233-2017-04086
Device Sequence Number10930196
Product Code NNX
UDI-Device Identifier00801741071089
UDI-Public(01)00801741071089
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,other
Initial Reporter Occupation Patient
Type of Report Initial,Followup
Report Date (Section B) 02/24/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date05/31/2021
Device Model Number36304
Device Catalogue Number36304
Device Lot NumberNGAT4366
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/07/2017
Initial Date Received by Manufacturer 07/14/2017
Supplement Date Received by Manufacturer02/22/2018
Initial Report FDA Received Date08/01/2017
Supplement Report FDA Received Date02/24/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-