| Model Number |
M004R9620N40 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Pericardial Effusion (3271)
|
| Date of Event |
08/04/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).
|
| |
|
Event or Problem Description
|
|
Same case as mdr id# 2134265-2017-08395 and 2134265-2017-08396.It was reported a pericardial effusion occurred.An intellamap orion¿ mapping catheter, polaris x¿ diagnostic catheter, and an intellanav oi ablation catheter were used during a pulmonary vein ablation procedure being conducted to treat atrial fibrillation.During the procedure the physician noticed a pericardial effusion.The physician felt the effusion occurred during mapping, but was uncertain which catheter caused or contributed to the event.It was noted there had been no device performance issues.A pericardiocentesis was performed and the patient underwent surgery to repair the hole.The patient was doing ¿very well¿ and was in stable condition.
|
| |
|
Additional Manufacturer Narrative
|
|
Device evaluated by mfr: the device was received for analysis following decontamination.The lot number of the returned device did not match the lot number originally reported.The device did not have any obvious visible defects.Continuity checks revealed no electrical opens or shorts, and all electrode, thermistor, and magnetic sensor resistances measured within specification.The steering knob and tension control knob functioned properly on both the lock and unlock positions.No abnormal resistance was felt when actuating the steering mechanism.Tip motion was evaluated and the device passed both the right and left curve tests.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The root cause is anticipated procedural complications as this event is a known physiological effect of the procedure and is noted within the dfu.(b)(4).
|
| |
|
Event or Problem Description
|
|
Same case as mdr id# 2134265-2017-08395 and 2134265-2017-08396.It was reported a pericardial effusion occurred.An intellamap orion¿ mapping catheter, polaris x¿ diagnostic catheter, and an intellanav oi ablation catheter were used during a pulmonary vein ablation procedure being conducted to treat atrial fibrillation.During the procedure the physician noticed a pericardial effusion.The physician felt the effusion occurred during mapping, but was uncertain which catheter caused or contributed to the event.It was noted there had been no device performance issues.A pericardiocentesis was performed and the patient underwent surgery to repair the hole.The patient was doing ¿very well¿ and was in stable condition.
|
| |
|