Model Number PG14300LF
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Perforation of Vessels (2135)
Date of Event 08/02/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).This case was reviewed and investigated according to philips volcano policy.Attempt to obtain "patient weight" was unsuccessful as the weight was not recorded.All reasonably known patient information is included in this report.Additional information: the physician wired down to the anterior tibial (at) with a light support wire.The target lesion was in the proximal at.This patient had an abrupt junction between the at and the tibial peroneal trunk (tpt) which made the takeoff of the at steep.The guidewire was biasing toward the carina of the tpt/at junction and could have been sub-intimal at this location.This is where a perforation occurred during atherectomy*.Per the analysis of the 0.14 guidewire, vessel tissue was found wrapped around the.014 guidewire.Treatment was not completed by the procedure.No damage was noted during prep.Resistance was felt on the 2nd pass (only made 2 passes).Device appeared intact after removal from the patient and no damage was observed.The catheter* was removed with difficulty first, after multiple attempts, to buddywire, exchange through crossing catheter, balloons, physician finally had to remove the guidewire.Nothing would advance past a certain point on the wire.* the atherectomy catheter noted is manufactured by phililps volcano and an initial report was submitted separately to the fda under mdr 2939520-2017-00073 on 09-01-2017 ((b)(4)).No tests/laboratory data was available.A serial number is not applicable to this device.The implant or explant dates are not applicable to this device.The device was investigated by the distributor.The guidewire was examined which revealed tissue wrapped around the distal tip section of the wire.The rest of the wire was unaffected.On the coiled distal section of the wire there was evidence that the coils were stretched due to the physician trying to feed the atherectomy catheter and balloons over the wire while meeting resistance from the wrapped tissue.The device functioned as intended.Foreign material (vessel tissue) was present on the guidewire which prevented the passage of the atherectomy catheter and balloon catheters.Manufacturing date is pending.The manufacturing documentation for this device was reviewed and the device met all quality and manufacturing release criteria.There were no nonconforming material reports or deviations noted that would contribute to the reported failure mode.This complaint will be monitored as part of complaint data analysis.
 
Event or Problem Description
It was reported for a therapeutic peripheral procedure the user plugged in atherectomy catheter device, flushed, made one pass that was fine, and came back to make the second pass.The atherectomy device almost stopped.The physician pulled back slightly and got it to work.When they tried to advance, it was like there was a blockage.They stopped, pulled the atherectomy device and did angiogram and saw the there was a substance on the wire.They then tried to advance a balloon down the wire and it would not go.They tried advancing it [the catheter] again but was unable.When they pulled the wire they saw something on the wire that had been preventing the pass.Patient experienced an event of perforated artery at anterior tibial.Patient was released as expected in stable condition.On (b)(6) 2017 the manufacturer's representative reported the patient was admitted to the hospital post-procedure.Vessel: 99% occlusion, located anterior tibial, moderately calcified.This event is being reported because there was a patient event during the procedure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MANDREL GUIDEWIRES OR M-WIRES
Common Device Name
WIRE, GUIDE, CATHETER
Manufacturer (Section D)
LAKE REGION MFG., INC
340 lake hazeltine dr.
chaska MN 55318
MDR Report Key6840276
Report Number2939520-2017-00074
Device Sequence Number18861052
Product Code DQX
UDI-Device Identifier00845225002763
UDI-Public(01)00845225002763(17)190131(10)10643211
Combination Product (Y/N)N
Initial Reporter StateAL
Initial Reporter CountryUS
PMA/510(K) Number
K080144
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/02/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/31/2019
Device Model NumberPG14300LF
Device Catalogue NumberPG14300LF
Device Lot Number10643211
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/09/2017
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/02/2017
Initial Report FDA Received Date09/01/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Other; Required Intervention;
Patient Age69 YR
-
-