BARD ACCESS SYSTEMS PER-Q-CATH PLUS 2F SINGLE-LUMEN PICC WITH STIFFENING STYLET INTERMEDIATE TRAY (3; PERCUTANEOUS, IMPLANTED, LONG TERM INTRAVASCULAR CATHETER
|
Back to Search Results |
|
| Model Number |
4132100 |
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The manufacturer has received the sample and will be evaluated.Results are expected soon.A lot history review (lhr) of rebt0172 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
Per sales rep, the facility reported that during priming of the catheter it leaked, squirting out saline.
|
| |
|
Additional Manufacturer Narrative
|
|
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a leak in the per-q-cath picc was confirmed, but where or when the catheter was damaged cannot be verified.One 2 fr per-q-cath picc was returned for evaluation.The picc was received with the stylet in the lumen.No evidence was found that the catheter length had been modified or the stylet repositioned within the lumen.A functional test revealed a leak in the 2fr tubing near the 24 cm depth mark.The leak site was microscopically examined and a longitudinal split was found on the external surface of the tubing.The catheter was cut longitudinally to examine the leak site from within the catheter, which revealed that the split was longer on the inner lumen wall.The adjoining surfaces of the split tubing revealed a granular appearance.This type of split can occur when the catheter is compressed against the stylet.The catheter may have been compressed against the stylet while in transit, storage, or preparation for insertion.The product ifu states, ¿avoid accidental device contact with sharp instruments and mechanical damage to the catheter material.Use only smooth-edged atraumatic clamps or forceps.¿ manipulation of the stylet within the lumen can also damage the catheter is the stylet is not wetted prior to repositioning.The ifu indicates to never use force to remove stylet.Resistance can damage the catheter.A lot history review (lhr) of rebt0172 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
Per sales rep, the facility reported that during priming of the catheter it leaked, squirting out saline.
|
| |
|