MAUDE Adverse Event Report: BOSTON SCIENTIFIC - GALWAY SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC - GALWAY SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM Back to Search Results
Model Number H7493926016250
Device Problems Balloon; Hole In Material
Event Date 08/27/2017
Event Type  Malfunction  
Manufacturer Narrative

Device is a combination product. (b)(4). Device evaluated by mfr. : the device has not been received for analysis. Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental med watch will be filed. (b)(4).

 
Event Description

It was reported that balloon pinhole occurred. The 80% stenosed target lesion was located in a moderately tortuous and severely calcified coronary artery. A 2. 50 x 16 synergy ii drug-eluting stent was advanced and difficulties were encountered crossing the lesion. During the first inflation of the stent delivery balloon at 16 atmospheres the balloon did not inflate and a pinhole was noted. The procedure was completed with a different device. No patient complications were reported and the patient's status was good.

 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameSYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM
Type of DeviceBIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC - GALWAY
Manufacturer (Section G)
BOSTON SCIENTIFIC - GALWAY
Manufacturer Contact
sonali arangil
one scimed place
maple grove , MN 55311
7634941700
MDR Report Key6880948
Report Number2134265-2017-09689
Device Sequence Number1
Product CodeNIQ
Report Source Manufacturer
Source Type COMPANY REPRESENTATIVE,HEALTH
Reporter Occupation
Type of Report Initial
Report Date 08/31/2017
1 Device Was Involved in the Event
0 PatientS WERE Involved in the Event:
Date FDA Received09/20/2017
Is This An Adverse Event Report? No
Is This A Product Problem Report? Yes
Device Operator HEALTH PROFESSIONAL
Device EXPIRATION Date01/30/2018
Device MODEL NumberH7493926016250
Device Catalogue Number39260-1625
Device LOT Number20260706
Was Device Available For Evaluation? No
Is The Reporter A Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/31/2017
Was Device Evaluated By Manufacturer? Device Not Returned To Manufacturer
Date Device Manufactured02/16/2017
Is The Device Single Use? Yes
Is this a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-