Model Number BA25-80/I20-40
Medical Device Problem Codes Collapse (1099); Improper or Incorrect Procedure or Method (2017); Malposition of Device (2616)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 11/24/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The devices involved in the event will not be returned for evaluation, they remain implanted in the patient.If additional information pertinent to the incident is obtained, a follow-up report will be submitted.
 
Event or Problem Description
During the initial procedure, while deploying the main body it was discovered through angio that the main body was placed above the renals and the iliac limbs were much higher compared to the original position.The physician attempted to snare the limbs to place it back in the iliac but the limbs collapse.A medtronic aortomonoiliac was placed and the physician performed a femoro-femora bypass to successfully resolve the issue.Patient is reported to be doing well.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AFX
Common Device Name
BIFURCATED STENT GRAFT
Manufacturer (Section D)
ENDOLOGIX
2 musick
irvine CA 92618
MDR Report Key7119766
Report Number2031527-2017-00672
Device Sequence Number19057439
Product Code MIH
UDI-Device Identifier00818009012210
UDI-Public(01)00818009012210(17)200327
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
P040002
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/27/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Expiration Date03/27/2020
Device Model NumberBA25-80/I20-40
Device Lot Number1668747009
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/27/2017
Initial Report FDA Received Date12/14/2017
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-