• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BIO-DETEK INCORPORATED PRO-PADZ RADIOLUCENT LIQUID GEL ELECTRODE; ELECTRODES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BIO-DETEK INCORPORATED PRO-PADZ RADIOLUCENT LIQUID GEL ELECTRODE; ELECTRODES Back to Search Results
Model Number 8900-2105-01
Medical Device Problem Code Failure To Adhere Or Bond (1031)
Health Effect - Clinical Code No Information (3190)
Date of Event 11/22/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Zoll medical corporation has not received the product for evaluation and this complaint is still under investigation.
 
Event or Problem Description
Complainant alleged that while attempting to defibrillate a (b)(6) male patient, the electrode pads would not adhere to the patient's skin.Complainant did not indicate that there was any adverse effect to the patient due to the reported malfunction.Please reference medwatch report 1218058-2017-00139, 1218058-2017-00140, and 1218058-2017-00141 for similar events reported from the same customer.
 
Additional Manufacturer Narrative
The electrode pads were returned to zoll medical corporation; the liquid gel from the center sponge was observed in several places on the adhesive foam.It was determined the liquid gel affected the adhesive properties of the foam, which inhibits patient/electrode adhesion.Evaluation of the retain electrodes did not reveal any irregularities that would have contributed to the reported event.It is noteworthy to mention the instructions for use warns "do not use if gel escaped from electrodes into packaging" and to "store flat".Analysis for reports of this type has not identified an increase in trend.Please reference medwatch report 1218058-2017-00139, 1218058-2017-00140, and 1218058-2017-00141 for similar events reported from the same customer.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRO-PADZ RADIOLUCENT LIQUID GEL ELECTRODE
Common Device Name
ELECTRODES
Manufacturer (Section D)
BIO-DETEK INCORPORATED
525 narragansett park drive
pawtucket RI 02861
MDR Report Key7138171
Report Number1218058-2017-00142
Device Sequence Number10780348
Product Code MKJ
UDI-Device Identifier10847946016408
UDI-Public10847946016408
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 12/04/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model Number8900-2105-01
Device Catalogue Number8900-2105-01
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/05/2017
Initial Date Received by Manufacturer 12/04/2017
Supplement Date Received by Manufacturer12/04/2017
Initial Report FDA Received Date12/21/2017
Supplement Report FDA Received Date02/27/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age65 YR
-
-