| Model Number |
48335312 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Weakness (2145); Spinal Cord Injury (2432)
|
| Date of Event |
12/02/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that; the surgeon was undertaking an anterior cervical discectomy and fusion with the intention of implanting a cage and screws.The clinical support specialist was in the case.The surgeon implanted the cage and screws and then decided to move one of the screws.At this point no x-ray was being used.The surgeon thought he had taken the screw out and handed the screwdriver back to the scrub nurse.The nurse stated that he did not have the screw and the surgeon suggested that he / the scrub team look for the screw.Not realizing that the first screw was still in situ, the surgeon then attempted to insert a different screw and found it difficult to insert.The surgeon said that the screw was difficult to insert and asked if there was a tool that could help.The clinical support specialist, also unaware that the screw was still implanted, suggested that a sharp shooter, awl or drill could potentially help.The surgeon then used an awl and a hammer to create a pathway for the second screw.However, this advanced the first screw past the point on the cage where it should stop.He then used a drill which advanced the screw further.He then put in a second screw which pushed the original one into the spinal canal.Once the cage and screws had been implanted, the patient was sent for x-ray and it was only then that the surgeon realized that 2 screws had been implanted, one on top of the other, and thus inserted to a depth which was double that of a single screw.The surgeon then immediately removed the cage and all screws and completed the case using a fresh cage.Post operatively the patient was reported to have some lower leg and upper arm weakness which has been recorded as a spinal cord injury by the hospital.Some recovery is expected but the likely extent of this recovery is currently unclear.
|
| |
|
Additional Manufacturer Narrative
|
|
Investigation is still underway.Investigation results will be provided once investigation is completed.
|
| |
|
Event or Problem Description
|
|
It was reported that; the surgeon was undertaking an anterior cervical discectomy and fusion with the intention of implanting a cage and screws.The clinical support specialist was in the case.The surgeon implanted the cage and screws and then decided to move one of the screws.At this point no x-ray was being used.The surgeon thought he had taken the screw out and handed the screwdriver back to the scrub nurse.The nurse stated that he did not have the screw and the surgeon suggested that he / the scrub team look for the screw.Not realising that the first screw was still in situ, the surgeon then attempted to insert a different screw and found it difficult to insert.The surgeon said that the screw was difficult to insert and asked if there was a tool that could help.The clinical support specialist, also unaware that the screw was still implanted, suggested that a sharp shooter, awl or drill could potentially help.The surgeon then used an awl and a hammer to create a pathway for the second screw.However, this advanced the first screw past the point on the cage where it should stop.He then used a drill which advanced the screw further.He then put in a second screw which pushed the original one into the spinal canal.Once the cage and screws had been implanted, the patient was sent for x-ray and it was only then that the surgeon realised that 2 screws had been implanted, one on top of the other, and thus inserted to a depth which was double that of a single screw.The surgeon then immediately removed the cage and all screws and completed the case using a fresh cage.Post operatively the patient was reported to have some lower leg and upper arm weakness which has been recorded as a spinal cord injury by the hospital.Some recovery is expected but the likely extent of this recovery is currently unclear.
|
| |
|
Event or Problem Description
|
|
It was reported that; the surgeon was undertaking an anterior cervical discectomy and fusion with the intention of implanting a cage and screws.The clinical support specialist was in the case.The surgeon implanted the cage and screws and then decided to move one of the screws.At this point no x-ray was being used.The surgeon thought he had taken the screw out and handed the screwdriver back to the scrub nurse.The nurse stated that he did not have the screw and the surgeon suggested that he / the scrub team look for the screw.Not realising that the first screw was still in situ, the surgeon then attempted to insert a different screw and found it difficult to insert.The surgeon said that the screw was difficult to insert and asked if there was a tool that could help.The clinical support specialist, also unaware that the screw was still implanted, suggested that a sharp shooter, awl or drill could potentially help.The surgeon then used an awl and a hammer to create a pathway for the second screw.However, this advanced the first screw past the point on the cage where it should stop.He then used a drill which advanced the screw further.He then put in a second screw which pushed the original one into the spinal canal.Once the cage and screws had been implanted, the patient was sent for x-ray and it was only then that the surgeon realised that 2 screws had been implanted, one on top of the other, and thus inserted to a depth which was double that of a single screw.The surgeon then immediately removed the cage and all screws and completed the case using a fresh cage.Post operatively the patient was reported to have some lower leg and upper arm weakness which has been recorded as a spinal cord injury by the hospital.Some recovery is expected but the likely extent of this recovery is currently unclear.
|
| |
|