Device Problem Signal Artifact/Noise (1036)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
Note: we have not completed our investigation of this event.We will file a follow-up emdr at the completion of the investigation.(b)(4).
 
Event Description
This complaint has been evaluated based on the information provided; there is no allegation of death or serious injury.The customer reported a ring artifact on brain studies.Engineering analysis has confirmed that this event has been determined to be a reportable issue due to the potential for image misinterpretation, because of a recognizable artifact.Therefore, this issue has been determined to be a reportable event.This event is currently under investigation.
 
Manufacturer Narrative
The customer reported a recognized ring artifact on brain studies.A philips field service engineer (fse) went onsite to evaluate the system.The fse investigated the system and determined the ring artifact was the result of a cracked compensator which is inside the a-plane collimator.The fse replaced the a-plane collimator assembly to resolve the issue.The fse confirmed that there was no harm to a patient, operator, or bystander; there was no image misinterpretation as a result of the artifact.The system is functional and in clinical use.This issue has been determined not to be a reportable event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BRILLIANCE AIR 40/64/UCT
Type of Device
SYSTEM, X-RAY, TOMOGRAPHY, COMPUTED
Manufacturer (Section D)
PHILIPS MEDICAL SYSTEMS (CLEVELAND), INC.
595 miner rd
cleveland OH 44143
MDR Report Key7153909
MDR Text Key96124991
Report Number1525965-2017-00163
Device Sequence Number1
Product Code JAK
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 12/11/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/29/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Other Device ID NumberN/A
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received12/11/2017
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-