Model Number M00514250
Medical Device Problem Code Activation, Positioning or Separation Problem (2906)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/12/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device code relates to problem code for the reported event of stent partially deployed.The device has not been received for analysis; therefore a failure analysis of the complaint device could not be completed.If any further relevant information is identified, a supplemental medwatch will be filed.
 
Event or Problem Description
It was reported to boston scientific corporation on (b)(6) 2017 that an ultraflex esophageal proximal release covered stent was to be used to treat a gastroesophageal junction stricture due to esophageal cancer during a stenting procedure performed on (b)(6) 2017.Reportedly, the patient's anatomy was not tortuous.According to the complainant, during the procedure, the physician started deploying the stent, however, the shaft was kinked and the stent was partially deployed.The procedure was completed a different device.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be stable.
 
Additional Manufacturer Narrative
A partially deployed ultraflex esophageal proximal release covered stent and delivery system was received for analysis.Visual examination of the returned device observed manipulation near the distal part.Functional analysis of the device found that the stent was able to be deployed without any resistance.The stent was measured to be within specifications.No issues noted with the green braided polyester suture and no other issues noted with the device.The damages noted with the device were consistent with the application of excessive force during usage.The investigation concluded that the cause of the reported event was most probably due to anatomical or procedural factor encountered during the procedure which limited the performance of the device.Therefore, the most probable root cause is operational context.A review of the device history record (dhr) was performed and confirmed that this device met all material, assembly and performance specifications at the time of release for distribution.A search of the complaint database revealed that no similar complaints exist for the specified lot.
 
Event or Problem Description
It was reported to boston scientific corporation on (b)(6) 2017 that an ultraflex esophageal proximal release covered stent was to be used to treat a gastroesophageal junction stricture due to esophageal cancer during a stenting procedure performed on (b)(6) 2017.Reportedly, the patient's anatomy was not tortuous.According to the complainant, during the procedure, the physician started deploying the stent, however, the shaft was kinked and the stent was partially deployed.The procedure was completed a different device.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAFLEX¿ ESOPHAGEAL NG
Common Device Name
PROSTHESIS, ESOPHAGEAL
Manufacturer (Section D)
BOSTON SCIENTIFIC - GALWAY
MDR Report Key7160717
Report Number3005099803-2017-03928
Device Sequence Number63651
Product Code ESW
UDI-Device Identifier08714729716112
UDI-Public08714729716112
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K091816
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 12/13/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/09/2019
Device Model NumberM00514250
Device Catalogue Number1425
Device Lot Number0020137743
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/12/2018
Initial Date Received by Manufacturer 12/13/2017
Supplement Date Received by Manufacturer01/26/2018
Initial Report FDA Received Date01/03/2018
Supplement Report FDA Received Date02/16/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-