Model Number 082135
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 12/11/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event or Problem Description
It was reported that the guidewire came apart during the procedure.No medical intervention was reported.
 
Additional Manufacturer Narrative
The reported event was confirmed.The exact root cause of stated defect is unknown.Received 1 used bard guidewire for evaluation.No hoop was returned.The safety wire was still present in the weld.The safety wire was broken and appearance showed it to be elongated with signs of stretching.The wire was wavy due to use, and distal end had coils unraveled.It is unknown whether the patient and/or procedural issues contributed to the event.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use state the following: "description: guidewires are used to provide access and facilitate passage of endourological instrumentation during urological procedures.They are offered in many different configurations that include: sizes (lengths and diameters), tip designs, coatings (hydrophilic and ptfe) and stiffness.The bard® nicore¿ wire has a nitinol core and a hydrophilic coating.The bard® hydro-glide¿ stainless steel guidewires are available with a hydrophilic coating.The bard® stainless steel guidewires are available with and without ptfe and are available in fixed and movable core.Indications: bard® guidewires are indicated to provide transurethral and/or percutaneous access into the bladder, ureter or renal pelvis.Contraindications: there are no known contraindications warning: inspect all guidewires for damage prior to use.Bending or kinking during or prior to placement could damage the guidewire.Do not attempt to use the guidewire if it has been damaged.Use of a damaged wire may result in damage to the urinary tract.Do not reshape the guidewire by any means.Attempting to reshape the guidewire may cause damage resulting in release of fragments into the urinary tract.Failure to exercise proper caution may result in damage to the urinary tract.Do not manipulate or remove the guidewire through a metal cannula or needle.This may result in destruction/separation of the outer jacket of the wire requiring retrieval.Use extreme caution when using a laser, making sure to avoid contact with the wire.Direct contact could result in damage / breakage to the wire.Attention should be paid to guidewire movement in the urinary tract.Before a guidewire is moved or torqued, tip movement should be examined under direct vision or fluoroscopy.Do not advance or withdraw a guidewire when resistance is encountered as perforation could occur.Sufficient guidewire length must remain exposed to maintain a firm grip on guidewire at all times.Failure to comply with the warnings could result in damage to the guidewire to include, but not limited to: wire breakage, abrasion of the coating, release of guidewire fragments into the urinary system, all of which might require intervention.This is a single use device.Do not resterilize any portion of this device.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of device, which may lead to device failure, and/or lead to injury, illness or death of the patient.Precautions: should be used only by physicians thoroughly trained in endourological guidewire techniques.Do not use dry gauze to manipulate the guidewire as this can damage the surface coating and make the wire tacky.Caution: federal (u.S.A.) law restricts this device to sale by or on the order of a physician.Potential complications: complications that may result from the use of a guidewire in a urological procedure include, but are not limited to: perforation, acute or delayed bleeding, tissue trauma, edema.Direction for use: the physician should select the proper size and length of the guidewire for the procedure being performed.The guidewire is packaged in a protective coil.For hydrophilic coating wires: hydrophilic coated guidewires require activation of their coating.Prior to removing the guidewire from the protective coil, inject sterile saline through the port to activate the lubricious coating.Remove the guidewire from the protective coil and carefully inspect the coil for separation, bends, kinks or a damaged tip.For ptfe wires: remove the guidewire from the protective coil and carefully inspect the coil for separation, bends, kinks or damaged tip.Introduce the guidewire, flexible end first, into the working channel of the endoscopes or percutaneously into the urinary tract.Advance the guidewire slowly into the desired position.Continuously confirm guidewire position either visually or under fluoroscopy.Carefully withdraw the guidewire taking care not to kink.Note: after use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and with applicable laws and regulations." (b)(4).
 
Event or Problem Description
It was reported that the guidewire came apart during the procedure.No medical intervention was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GUIDEWIRE STRAIGHT FIXED CORE PTFE-COATED .035" (0.889MM) 145CM, STERILE
Common Device Name
GUIDEWIRE
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key7167925
Report Number1018233-2018-00037
Device Sequence Number19061781
Product Code EZB
UDI-Device Identifier00801741052835
UDI-Public(01)00801741052835
Combination Product (Y/N)N
Initial Reporter StateME
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/15/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/31/2022
Device Model Number082135
Device Catalogue Number082135
Device Lot NumberGFBU2358
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/16/2018
Initial Date Received by Manufacturer 12/14/2017
Supplement Date Received by Manufacturer03/14/2018
Initial Report FDA Received Date01/05/2018
Supplement Report FDA Received Date03/15/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age74 YR
-
-