BARD ACCESS SYSTEMS PER-Q-CATH PLUS 2F SINGLE-LUMEN PICC WITH STIFFENING STYLET INTERMEDIATE TRAY; CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS Back to Search Results
Model Number 4132100
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The manufacturer has received the sample and will evaluate.Results are expected soon.A lot history review (lhr) of rebs2483 showed one other similar product complaint(s) from this lot number.
 
Event or Problem Description
The facility reported to the sales rep that the rn inserted the picc and after removing the stylet, a leak was noted at the 2cm mark.The picc was removed and another picc was placed successfully.No patient harm reported.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a leak is confirmed and was determined to be use related.One 2 fr per-q-cath was returned for evaluation.An initial visual observation showed the catheter was returned in two segments.Blood residue was observed on the returned sample.The proximal segment of the catheter was flushed with a 12 ml syringe of water and a leak was observed approximately 2.1 cm distal to the distal end of the strain relief.A microscopic observation revealed a diagonal split in the catheter at the leak site.The split was observed to be mostly straight with one slightly curved corner.The sample was dissected in order to observe the inner wall of the catheter.The split appeared to be slightly more extensive on the inner surface of the catheter than the outer surface.What appeared to be abrasive damage could be seen on the inner wall opposite of the split.The damage observed on and within the catheter is typical of damage caused by excessive force or friction from a stylet.As a note, the product ifu states: ¿catheter stylet must be wetted prior to stylet repositioning or withdrawal¿ and ¿never use force to remove the stylet.Resistance can damage the catheter.If resistance or bunching of the catheter is observed, stop stylet withdrawal and allow the catheter to return to normal shape.Withdraw both the catheter and stylet together approximately 2 cm and reattempt stylet removal.Repeat this procedure until the stylet is easily removed.Once the stylet is out, advance the catheter into the desired position.¿ a lot history review (lhr) of rebs2483 showed one other similar product complaint(s) from this lot number.
 
Event or Problem Description
The facility reported to the sales rep that the rn inserted the picc and after removing the stylet, a leak was noted at the 2cm mark.The picc was removed and another picc was placed successfully.No patient harm reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PER-Q-CATH PLUS 2F SINGLE-LUMEN PICC WITH STIFFENING STYLET INTERMEDIATE TRAY
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7167975
Report Number3006260740-2017-02379
Device Sequence Number13476886
Product Code LJS
UDI-Device Identifier00801741035210
UDI-Public(01)00801741035210
Combination Product (Y/N)N
Initial Reporter StateTN
Initial Reporter CountryUS
PMA/510(K) Number
K954104
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 02/14/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number4132100
Device Catalogue Number4132100
Device Lot NumberREBS2483
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/29/2017
Event Location Hospital
Initial Date Received by Manufacturer 12/29/2017
Supplement Date Received by Manufacturer01/26/2018
Initial Report FDA Received Date01/05/2018
Supplement Report FDA Received Date02/14/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-