| Model Number |
ETBF2513C166E |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Aneurysm (1708)
|
| Date of Event |
12/19/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Information references the main component of the system.Other relevant devices are: etlw1613c156e, s/n: (b)(4); use by date: 22-jan-2015; upn # (b)(4).Etew1313c82e, s/n: (b)(4); use by date: 2-nov-2014; upn # (b)(4).A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
An endurant stent graft system was implanted in a patient for the endovascular treatment of an unknown sized abdominal aortic aneurysm on (b)(6) 2013.It was reported that during a follow up ct, that the aneurysm had enlarged.The device does not appear to have an endoleak but the physician would prefer to explant the stent graft.As per the physician, the cause of the event cannot be confirmed.An intervention is planned to remove the stent graft system.No additional clinical sequelae were reported and the patient will be monitored.
|
| |
|
Additional Manufacturer Narrative
|
|
If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Device evaluation summary; from the examination of the returned devices and clinical information provided, the cause of the aaa expansion could not be determined.The bifurcate was returned transected proximally between covered stent rings; the proximal stent (including the suprarenal stents) were not returned.Both the bifurcate ipsilateral limb and contralateral limb were also transected.The ipsi limb was transected between rings (near the level of the gate ring), and the ipsi limb was seen having been extended with a limb 2 stent rings.The contra limb was placed inside the gate (overlapping 4 stent rings) and was transected distally ~40mm (4 rings) below the end of the gate ring.The distal segment of the contra limb was not returned.The returned stent graft components were minimally angulated.Other than the stent graft fabric transection cuts noted above, no device integrity issues were observed; no fabric holes, stent fractures or suture breaks were found.Analysis of the returned devices did not reveal any stent graft characteristics that could explain the reported aaa expansion.The bifurcate 1st covered stent suprarenal stents and the distal contra limb were not returned which limited the extent of the analysis.Films were not available for review; therefore, the stent graft in-vivo configuration and endoleak assessment during the 53 month implant duration could not be performed.It is possible that the aaa expansion was due to a type v endoleak; endotension.
|
| |
|