Model Number H7493926008270
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/21/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device is a combination product.(b)(4).
 
Event or Problem Description
It was reported that shaft break occurred.The target lesion was located in the circumflex artery.After a guide catheter and a guide wire crossed the lesion, a 2.75 x 8mm synergy ii drug-eluting stent was advanced to treat the lesion; however, it was noted that the stent delivery system was fractured while it was in the guide catheter.A balloon was inflated distally inside the guide catheter and then the guide wire and the stent was removed.The procedure was completed with a different device.No patient complications were reported.
 
Additional Manufacturer Narrative
Device evaluated by mfr.: synergy ii us mr 2.75 x 8mm stent delivery system was returned for analysis.A visual and microscopic examination of the crimped stent found no issues with the stent.There were no signs of damage, stretching or lifting of the stent struts.The stent showed no signs of movement and was set between the proximal and distal marker bands.The crimped stent outer diameter was measured and was within maximum crimped stent profile measurement.The balloon was reviewed and no issues were noted.The balloon wings were tightly wrapped and evenly folded and were not subjected to positive pressure.A visual and tactile examination of the hypotube found a hypotube break 616mm distal to the distal end of the strain relief.Multiple hypotube kinks were also noted.A visual and tactile examination of the shaft polymer extrusion revealed no issues.A visual and microscopic examination of the tip found no issues.No other issues were identified during the product analysis.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The investigation conclusion is handling damage as the complaint was caused by handling of the device or portion of the device without direct patient contact.(b)(4).
 
Event or Problem Description
It was reported that shaft break occurred.The target lesion was located in the circumflex artery.After a guide catheter and a guide wire crossed the lesion, a 2.75 x 8mm synergy ii drug-eluting stent was advanced to treat the lesion; however, it was noted that the stent delivery system was fractured while it was in the guide catheter.A balloon was inflated distally inside the guide catheter and then the guide wire and the stent was removed.The procedure was completed with a different device.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM
Common Device Name
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC - GALWAY
MDR Report Key7201041
Report Number2134265-2017-13300
Device Sequence Number10943419
Product Code NIQ
UDI-Device Identifier08714729839989
UDI-Public08714729839989
Combination Product (Y/N)N
Initial Reporter StateNE
Initial Reporter CountryUS
PMA/510(K) Number
P150003
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 12/21/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/03/2018
Device Model NumberH7493926008270
Device Catalogue Number39260-0827
Device Lot Number0020526035
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/29/2017
Initial Date Received by Manufacturer 12/21/2017
Supplement Date Received by Manufacturer01/26/2018
Initial Report FDA Received Date01/17/2018
Supplement Report FDA Received Date02/20/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age80 YR
-
-