Catalog Number T5-2530-191-US
Medical Device Problem Code Device Dislodged or Dislocated (2923)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 12/21/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Results: examination of the lot history record showed that the lot passed all acceptance criteria.Conclusion: the circumflex artery was reported to have had high tortuosity.The current ifu includes the following contraindication: "target lesion has excessive tortuosity unsuitable for stent delivery and deployment.".
 
Event or Problem Description
The stent separated from the balloon in the patient's vasculature.The physician noted that separation occurred after delivering in a tortuous circumflex artery.There was no injury to patient, and device was snared out through femoral arterial sheath.No subsequent tryton stent was used in this case.What was the target lesion? circumflex.Was there difficulty reaching the lesion? yes - very torturous.Was there difficulty crossing the lesion? yes.Did the device prep normally (i.E.Maintain negative pressure)? yes.Was there any resistance/friction while inserting the balloon through the rotating hemostatic valve? no.Was there any resistance/friction while inserting the balloon through the guide catheter? no.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRYTON SIDE BRANCH STENT
Common Device Name
BARE METAL CORONARY STENT
Manufacturer (Section D)
TRYTON MEDICAL, INC.
1000 park forty plaza
suite 325
durham NC 27713
MDR Report Key7207143
Report Number3007210870-2018-00001
Device Sequence Number1173498
Product Code MAF
UDI-Device Identifier00894588002132
UDI-Public00894588002132
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
P150039
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 12/22/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Expiration Date02/28/2019
Device Catalogue NumberT5-2530-191-US
Device Lot NumberUBC01B1000
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/09/2018
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/22/2017
Initial Report FDA Received Date01/19/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-