BARD ACCESS SYSTEMS HICKMAN HEMODIALYSIS/APHERESIS CATHETER 13.5F DUAL-LUMEN CATHETER, 45CM OVERALL; CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS Back to Search Results
Model Number 0600450
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 01/08/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device has not been returned to the manufacturer, at this time, for evaluation.A lot history review (lhr) of rezg1488 showed no other similar product complaint(s) from this lot number.Device not returned at this time.
 
Event or Problem Description
It was reported by the facility that they had a hickman catheter that had multiple holes in it.They stated the catheter had two holes in the blue lumen and one in the red lumen prior to the y-site.No patient injury reported.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a leak in the extension legs was confirmed, and the damaged appeared to be use related.One hickman dialysis catheter was returned for investigation.Evidence of use was observed on the sample.Blood residue was visible within the fibers of the cuff.Debris was observed on the clamps.A functional test revealed spraying leaks from each extension leg.The leaks were located between the bifurcation and the extension leg oversleeve.The extension legs were cut open to examine the leak sites within the lumen.Impressions from what appeared to be the coils of a guidewire were visible around the hole in the extension leg with the blue luer adaptor.Due to the condition of the sample, it appeared that the hickman dialysis catheter was damaged during use.The holes may have been created if the extension legs were clamped over the guidewire.The product ifu states, ¿avoid accidental device contact with sharp instruments and mechanical damage to the catheter material.¿ the ifu also states, ¿avoid perforating, tearing or fracturing the catheter when using a guidewire.¿ a lot history review (lhr) of rezg1488 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported by the facility that they had a hickman catheter that had multiple holes in it.They stated the catheter had two holes in the blue lumen and one in the red lumen prior to the y-site.No patient injury reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HICKMAN HEMODIALYSIS/APHERESIS CATHETER 13.5F DUAL-LUMEN CATHETER, 45CM OVERALL
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7224849
Report Number3006260740-2018-00061
Device Sequence Number1023066
Product Code LJS
UDI-Device Identifier00801741037443
UDI-Public(01)00801741037443
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K830233
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/29/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0600450
Device Catalogue Number0600450
Device Lot NumberREZG1488
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/08/2018
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer03/05/2018
Initial Report FDA Received Date01/29/2018
Supplement Report FDA Received Date03/29/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-