Model Number 520-01-238
Health Effect - Clinical Code No Code Available (3191)
Date of Event 01/22/2018
Type of Reportable Event Serious Injury
Event or Problem Description
Revision surgery - due to the patient having a failed total shoulder arthroplasty and needing to convert to a reverse.
 
Additional Manufacturer Narrative
The reason for this revision surgery was due to a failed total shoulder arthroplasty that needed to be converted to a reverse.The previous surgery and the revision detailed in this investigation occurred 6 years apart.There is no information in this complaint about any patient injuries, activities, or accidents that may have contributed to the need for this revision surgery.There are no reported pre-existing patient health conditions.Initial or prolonged hospitalization was required.The healthcare professional indicated there was no delay in surgery and another suitable device was available for use.The revision surgery was completed as intended.The device was disposed of at the hospital and not made available to (b)(6) surgical for examination.A review of the implant device history records (dhr) shows that the reported components used in the previous surgery met design and manufacturing requirements.There was one (1) non-conforming material report (ncmr) associated with the part 520-01-238 (lot-190g1001) listed in the complaint.Non-conforming material report (ncmr) 15273 documents 1 part (out of 15 parts) scrapped for code v9 - specification.Per material specification 10 engraving is not legible.The device was verified to have gone through an acceptable sterilization process and was within its expiration date at the time of use during the previous surgery.Customer complaint history of the reported device showed no present trends or on-going issues that are in need of review.The root cause of this complaint was a revision surgery due to a failed total shoulder arthroplasty being converted to a reverse.There were no findings during this investigation that indicate that the reported device was defective.There are multiple factors that may contribute to an event that are outside of the control of (b)(6) surgical.Inventory containment is not required as there are no indications of a product or process issue affecting implant safety or effectiveness.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TURON SHOULDER
Common Device Name
TURON PEGGED GLENOID IMPLANT, SIZE 38
Manufacturer (Section D)
ENCORE MEDICAL L.P.
9800 metric blvd
austin TX 78758 5445
MDR Report Key7225842
Report Number1644408-2018-00091
Device Sequence Number945139
Product Code KWS
UDI-Device Identifier00888912024945
UDI-Public(01)00888912024945
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K123982
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2012
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/07/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date10/28/2015
Device Model Number520-01-238
Device Catalogue Number520-01-238
Device Lot Number190G1001
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 01/22/2018
Supplement Date Received by Manufacturer03/06/2018
Initial Report FDA Received Date01/29/2018
Supplement Report FDA Received Date03/07/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
520-00-000, LOT 878C1075; 520-01-010, LOT 455G1034; 520-38-018, LOT 53993328; 520-00-000, LOT 878C1075; 520-01-010, LOT 455G1034; 520-38-018, LOT 53993328
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age71 YR
-
-