Model Number 3120
Medical Device Problem Codes Failure to Capture (1081); Communication or Transmission Problem (2896)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 12/28/2017
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
As no further information concerning this report is expected, our investigation is complete.This investigation will be updated should further information be provided.
 
Event or Problem Description
Boston scientific received information that during a routine in clinic follow up, upon completion of threshold testing with this pacemaker and another manufacturer's right ventricular (rv) lead, the end test button was selected on the programmer, however, a couple more beats of ventricular pacing were observed with no capture resulting in greater than 2 seconds of asystole before the test actually ended.It was noted that the initial test was performed using radio frequency (rf) telemetry.A second threshold test was performed using wanded telemetry, however, produced the same result.No adverse patient effects were reported.Boston scientific technical services (ts) reviewed the test strip and discussed that the end test command was likely not received by the device until 1-2 seconds after the end test button was pressed.Ts discussed that this delay is commonly associated with telemetry interference.This product remains implanted and in service.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZOOM
Manufacturer (Section D)
EXTERNAL MANUFACTURER
MDR Report Key7227318
Report Number2124215-2018-01294
Device Sequence Number11012406
Product Code LWS
UDI-Device Identifier00802526582004
UDI-Public00802526582004
Combination Product (Y/N)N
Initial Reporter StateME
Initial Reporter CountryUS
PMA/510(K) Number
P910077/S046
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Medical Equipment Company Technician/Representative
Type of Report Initial
Report Date (Section B) 12/28/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Model Number3120
Other Device ID NumberZOOM LATITUDE PROGRAMMER
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/28/2017
Initial Report FDA Received Date01/30/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age87 YR
-
-