Catalog Number 13200111
Device Problems Fracture (1260); Adverse Event Without Identified Device or Use Problem (2993); Positioning Problem (3009)
Patient Problems No Consequences Or Impact To Patient (2199); No Information (3190)
Event Date 01/01/2018
Event Type  malfunction  
Manufacturer Narrative
Once the investigation has been completed, any additional information will be reported in a supplemental report.
 
Event Description
The surgeon reported to the sales representative that "the position during the distale locking was not correct and the drill fractured during the distal locking.
 
Manufacturer Narrative
Evaluation revealed the target device gamma3® to be the primary device.The reported event of alleged targeting inaccuracy could not be confirmed, since the returned device is conforming to specifications and fully functional.Although a real root cause could not be determined the alleged event is most likely caused due to a suboptimal intra-operative procedure and has to be classified as user-customer-user error.The device inspection revealed the following: the device returned passed the pre-operative function test as intended.Neither a proximal mistargeting nor a distal mistargeting could be confirmed.Nevertheless, with respect to the long service life the device should not be used any longer.Potentially reduced accuracy in guidance is usually found during functional check (required per ifu).In case of any deviation it is realized prior to use.Pre-supposing that targeting accuracy for drilling was confirmed by pre-operative check it was concluded that the event(s) were mainly based in the intra-operative procedure.Reasons for misaligned drilling are various.Potential miss-targeting can also be caused but is not limited by e.G.: loosening of the nail holding bolt during insertion of the nail.Repeated tightening of the nail holding screw prior to distal targeting / drilling is recommended.Not realized unintended loosening of the attachment knob (will lead to release of the drill sleeve).No use of drill with centre tip / unfavourable bone contour.Drilling without drill guiding sleeve.Using blunt or damaged drill.High forces applied to the target device during drilling eventually leading to unintended distortion in the system of drill, sleeve, target device and nail.A review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.
 
Event Description
The surgeon reported to the sales representative that "the position during the distale locking was not correct and the drill fractured during the distal locking.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TARGET DEVICE GAMMA3®
Type of Device
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
MDR Report Key7232535
MDR Text Key98854580
Report Number0009610622-2018-00038
Device Sequence Number1
Product Code HSB
Combination Product (y/n)N
PMA/PMN Number
K123401
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 04/11/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/31/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number13200111
Device Lot NumberKME908755
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/05/2018
Date Manufacturer Received03/19/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-