BARD ACCESS SYSTEMS POWERPICC SOLO CATHETER 4F RADIOLOGY BASIC TRAY (SINGLE-LUMEN); CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
|
Back to Search Results |
|
| Model Number |
N/A |
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
01/15/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device has not been returned to the manufacturer, at this time, for evaluation.A lot history review (lhr) of rebs2018 showed no other similar product complaint(s) from this lot number.Device has not yet been returned for evaluation.
|
| |
|
Event or Problem Description
|
|
It was reported that on 5 cm below the wing of the picc there was a leak.The health care professional thought it was insertion error as the picc was brand new and once it migrated out a few cms, it began to leak.The picc was removed and replaced.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a catheter leak was confirmed and the cause appears to be use related.The product returned for evaluation was a 4fr s/l powerpicc solo catheter.The investigation findings are consistent with damage accumulated through flexural fatigue.Flexural fatigue occurs due to cyclic kinking of the catheter tube in which physiological, placement, usage, and mechanical factors may gradually form a crack(s) in the catheter.The returned product sample was evaluated and a split was observed between the 6cm-7cm depth markings (8.0cm from the molded joint).The catheter split was typical of flexural fatigue, and the characteristics observed which supported this type of failure included: damage which was circumferentially aligned.Fracture edges which were rounded and polished due to repeated material wear.'c' shaped impressions leading into the fracture site which are consistent with material buckling due to movement which caused the fracture edges to be pressed together.The damage was centered within a preferential kink at the same site.An examination of the catheter structure revealed no potential damage/defect related to manufacture of the product.A lot history review (lhr) of rebs2018 showed no other similar product complaint(s) from this lot number.
|
| |
|
Event or Problem Description
|
|
It was reported that on 5 cm below the wing of the picc there was a leak.The health care professional thought it was insertion error as the picc was brand new and once it migrated out a few cms, it began to leak.The picc was removed and replaced.There was no reported patient injury.
|
| |
|