Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 01/16/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The cause for the discordant total hcg results is unknown.The customer reported a falsely high result on a patient for total hcg when tested on the advia centaur xp.The falsely high result was reproduced when the same sample was run on another advia centaur xp.A second sample drawn at the same time from this patient results negative for total hcg.Quality control and other patient samples are not affected.All other patients are resulting as expected.Possible cause could be either the initial wrong sample was run or there was a preanalytical issue with the sample itself.Possible preanalytical factors include incomplete clotting and the formation of fibrin.The customer continues to run controls and patients for total hcg without further concern.The instrument is performing within specifications.No further evaluation of the device is required.The ifu states in the interpretation of results section: "results of this assay should always be interpreted in conjunction with patient's medical history, clinical presentation and other findings." mdr 1219913-2018-00018 was filed for the same event.
 
Event or Problem Description
A discordant positive advia centaur xp total hcg result was obtained for a patient sample.A second specimen from the same draw was tested and the result was negative.The discordant results were reported to the physician and questioned.No corrected report was issued.The patient is undergoing acne treatments and taking acutaine.It is unknown if the patient is pregnant or not.It is unknown if patient treatment was prescribed or altered.There was no report of adverse health consequences due to the discordant total hcg result.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR XP TOTAL HCG
Common Device Name
TOTAL HCG
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
511 benedict avenue
tarrytown NY 10591 5097
MDR Report Key7260735
Report Number1219913-2018-00076
Device Sequence Number19023504
Product Code JHI
UDI-Device Identifier00630414505183
UDI-Public00630414505183
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K925277
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,user faci
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 02/09/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/10/2018
Device Model NumberN/A
Device Catalogue Number10331723
Device Lot Number06060294
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/17/2018
Initial Report FDA Received Date02/09/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age15 YR
-
-