Catalog Number 7510400
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Injury (2348)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported that the patient underwent fusion surgery in which rhbmp-2/acs was implanted.On (b)(6) 2010: the patient was pre-operatively diagnosed with spinal reoperation.Spinal disc herniation.Spinal disc degeneration.Spinal stenosis.Spinal instability.Status post previous lumbar laminectomy l3 to s1 and underwent the following procedures: gill laminectomy l2-l3, l3-l4, l4-l5, l5-s1.Lumbar discectomy, l4-l5, l5-s1.Resection of epidural scar.Neurolysis of l5 nerve roots bilaterally.Code 22 reoperation.Use of intraoperative fluoroscopy.Fusion, posterolateral l2, l3, l4-l5, and s1 fusion, autograft and bmp.Fusion posterior lumbar interbody l4-l5 autograft.Fusion posterior lumbar interbody l5-s1 autograft, allograft, and bmp.Instrumentation machine tooled bone dowel, l4-l5 posterior lumbar interbody, machine tooled bone dowel l5-s1 posterior lumbar interbody.Screws l2, l3, l4-l5, and s1.Placement of epidural morphine.As per op-notes,¿ the locally obtained bone was mixed with bmp and placed posterolaterally for fusion at l2, l3, l4, l5 and s1.The interspace was distracted and via the posterior lumbar interbody route large volumes of autograft and bmp was placed into the vertebral space at l4-l5.¿ the patient tolerated the procedure well without any intraoperative complications.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFUSE BONE GRAFT
Common Device Name
FILLER, RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN, COLLAGEN SCAFFOLD WITH MET
Manufacturer (Section D)
MEDTRONIC SOFAMOR DANEK USA, INC
4340 swinea rd
memphis TN 38118
MDR Report Key7277610
Report Number1030489-2018-00244
Device Sequence Number16642637
Product Code NEK
UDI-Device Identifier00681490843805
UDI-Public00681490843805
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
P000058
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2010
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Attorney
Type of Report Initial
Report Date (Section B) 02/16/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/01/2012
Device Catalogue Number7510400
Device Lot NumberM110806AAH
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/29/2018
Initial Report FDA Received Date02/16/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-