MAUDE Adverse Event Report: SMITHS MEDICAL ASD, INC. DELTEC® PORT-A-CATH®II POWER P.A.C. IMPLANTABLE ACCESS SYSTEM; PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITHS MEDICAL ASD, INC. DELTEC® PORT-A-CATH®II POWER P.A.C. IMPLANTABLE ACCESS SYSTEM; PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR Back to Search Results
Catalog Number 21-4471-24
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code Pain (1994)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
See mfr: 3012307300-2018-00279, 3012307300-2018-00281, 3012307300-2018-00282, 3012307300-2018-00283.
 
Event or Problem Description
It was reported that the explanting doctor noticed holes in the catheter of a deltec® port-a-cath®ii power p.A.C.Implantable access system.Issues with the catheter had to be explanted when one patient complained of pain.There was no patient injury associated with this occurrence.
 
Additional Manufacturer Narrative
One used deltec® port-a-cath®ii power p.A.C.Implantable access system with an attached length of catheter measuring 7.5 inches was received for investigation.A visual inspection was performed and no holes were detected, however it did find two longitudinal slits, both approximately ¼ inch in length and located two inches from where it had been attached to the portal.The location and physical characteristics of the slits are consistent with the catheter having been exposed to first rib/clavicle compression syndrome as is described in the product ifu section ii warnings, 3rd bullet.There was no evidence found to suggest the event was caused from an intrinsic defect in the product.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DELTEC® PORT-A-CATH®II POWER P.A.C. IMPLANTABLE ACCESS SYSTEM
Common Device Name
PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR
Manufacturer (Section D)
SMITHS MEDICAL ASD, INC.
1265 gray fox road
st. paul MN 55112
MDR Report Key7278786
Report Number3012307300-2018-00280
Device Sequence Number19331203
Product Code LJT
UDI-Device Identifier10610586032745
UDI-Public10610586032745
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
PMA/510(K) Number
K072657
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source user facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/16/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date02/01/2020
Device Catalogue Number21-4471-24
Device Lot Number2966265
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/15/2018
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/09/2018
Supplement Date Received by Manufacturer02/23/2018
Initial Report FDA Received Date02/16/2018
Supplement Report FDA Received Date03/16/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-