ETHICON INC. PDS PLUS SUTURE 60"(150CM) 0 VIO; SUTURE, SURGICAL, ABSORBABLE Back to Search Results
Catalog Number PDP990G
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 02/01/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The device history records were reviewed and the manufacturing criteria was met prior to the release of this lot.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.1.What measures were taken to retrieve the broken piece? 2.Was there any additional tissue damage as a result of searching for the needle piece? 3.Were x-rays taken to locate the needle piece(s)? 4.Was the patient brought back to or to have needle removed or was the needle removed during the initial procedure?.
 
Event or Problem Description
It was reported that a patient underwent a wound closure on (b)(6) 2018 and suture was used.During the procedure, while closing fascia, the one-quarter end of the needle closest to the suture broke in two while the doctor was using the suture in the standard designed manner, utilizing a needle driver.A broken portion of the needle fell into the patient's abdominal cavity but was fully retrieved by the doctor.All pieces of the suture needle were removed and accounted for.It was not reported how the procedure was completed.There were no adverse patient consequences reported.Additional information has been requested.
 
Additional Manufacturer Narrative
Pc-(b)(4).The actual device was returned for evaluation.Upon evaluation, a fracture was observed in the body of the needle.The needle was received in two pieces, only one of the mating fracture surfaces was examined for this evaluation.A microscope was used to examine the fracture surfaces and surrounding area of the needle.The fracture surfaces were examined in multiple locations in order to determine the fracture mode.The evaluation revealed the fracture was predominately composed of microvoid coalescence, which is evidence of a ductile overload failure.Although evidence of a brittle failure was observed in the form of small areas of transgranular cleavage; mechanical damage and a cup-and-cone shaped fracture observed coincidental to the fracture provide additional evidence that the failure was induced by mechanical deformation leading to ductile overload.This was a ductile fracture.The evidence of this examination indicates that the breakage occurred from mechanical deformation, indents and scratches, due to gripping, bending and overstressing of the needle.  there is no evidence of any material flaw that would cause premature failure.
 
Additional Manufacturer Narrative
Product complaint # pc-(b)(4).Additional information was requested and the following was obtained: 1.What measures were taken to retrieve the broken piece? needle was found easily.2.Was there any additional tissue damage as a result of searching for the needle piece? no.3.Were x-rays taken to locate the needle piece(s)? no.4.Was the patient brought back to or to have needle removed or was the needle removed during the initial procedure? no.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PDS PLUS SUTURE 60"(150CM) 0 VIO
Common Device Name
SUTURE, SURGICAL, ABSORBABLE
Manufacturer (Section D)
ETHICON INC.
p.o. box 151, route 22 west
somerville NJ 08876 0151
MDR Report Key7282236
Report Number2210968-2018-70930
Device Sequence Number135721
Product Code NEW
UDI-Device Identifier10705031048713
UDI-Public10705031048713
Combination Product (Y/N)N
Initial Reporter StateOK
Initial Reporter CountryUS
PMA/510(K) Number
K061037
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/21/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/31/2019
Device Catalogue NumberPDP990G
Device Lot NumberLJ6470
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/23/2018
Initial Date Received by Manufacturer 02/01/2018
Supplement Date Received by Manufacturer02/21/2018
03/23/2018
Initial Report FDA Received Date02/20/2018
Supplement Report FDA Received Date02/23/2018
03/27/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-