| Catalog Number |
AR-8730-24H |
| Health Effect - Clinical Code |
Pain (1994)
|
| Date of Event |
01/08/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
No further patient information was provided at the time of this report or made available in response to follow-up communication.No additional adverse consequences have been reported from this event.This device is used for treatment.Device history record review revealed nothing relevant to this event.The explanted device was requested for evaluation but was not yet returned.The cause of the event could not be determined from the information available and without device evaluation.The event states that the patient was still in a period of recovery when the doctor found that his hardware failed (broke).The most likely cause of this event is failure to properly follow the post-op rehab protocol.The directions for use states: post-operatively, until healing is complete the fixation provided by this device should be protected.The post-operative regimen prescribed by the physician should be strictly followed to avoid adverse stresses applied to the implant.The potential causes of this event are being communicated to the event reporter.If additional relevant information is received, a follow-up report will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported by a workers compensation exchange staff member, through the arthrex website, that a patient had wrist surgery on (b)(6) 2017.During the procedure an arthrex cannulated screw was put in his wrist.Patient was still in a period of recovery when the doctor found that his hardware failed (broke).No information has been provided initially regarding if a revision surgery was performed or has been scheduled.Follow-up investigations: op report (b)(6) 2018: patient had suffered an on the job accident several weeks prior to his (b)(6) 2017 procedure for left wrist capitate lunate fusion.During this procedure an arthrex 24 mm cannulated mini screw was implanted.Approximately two weeks prior to follow up patient started developing pain.X-rays taken noted his hardware has broken in the capitate.Op report (b)(6) 18: patient underwent a revision procedure on (b)(6) 2018 during which the lunate-capitate fusion was encountered.It was noted this was a partial fusion.The screw was identified and removed without issue.The procedure was completed using another manufacturer's product.Part number of the screw that was explanted was ar-8730-24h, lot 1299539.
|
| |
|
Search Alerts/Recalls
|
|
|