| Model Number |
02.111.631 |
| Medical Device Problem Code |
Failure to Align (2522)
|
| Health Effect - Clinical Code |
No Known Impact Or Consequence To Patient (2692)
|
| Date of Event |
01/24/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Device malfunctioned intra-operative.Device was not implanted/explanted.Device is expected to be returned for manufacturer review/investigation, but has not been received yet.Device evaluation/investigation could not be completed; no conclusion could be drawn as product was not returned to manufacturer.Device history records review could not be completed without lot number.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported that during a distal radius fracture procedure on (b)(6) 2018, the surgeon noted a malfunction of a distal variable angle plate.As the surgeon was placing the first distal variable angle buttress pin he indicated that it would not lock into the plate despite the appropriate drill guide being used.On a visual inspection of the hole in the plate, the surgeon noted that it did not look as he expected.Another plate was selected and used with the concomitant surgical devices; the drill guide, drill bit, and buttress pin.All devices (used also with the first plate) functioned as expected with the alternative plate.The surgery was successfully completed with no consequence to the patient.Concomitant devices reported: drill guide (par# unknown, lot# unknown, quantity 1), drill bit (part# unknown, lot# unknown, quantity 1), buttress pin (part# unknown, lot# unknown, quantity 1).This report is for one (1) 2.4mm va-lcp 2-clmn vlr dstl radius pl 6h hd/3h shaft/left.This is report 1 of 1 for (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
The subject device has been received and the product evaluation is in progress.No conclusion can be drawn.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Further it was reported that there was a 3-minute delay in the procedure; the time it took for the surgeon to retrieve a new plate.
|
| |
|
Additional Manufacturer Narrative
|
|
Dhr review was completed.Part: 02.111.631 , lot: l645546 , manufacturing site: (b)(4).Release to warehouse date: 30.Nov.2017.Nr-0084450 was generated during production.This ncr documented a documentation issue which was detected at lot release process step.This deviation has no influence on reported issue.Review of the device history record showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.Customer quality conducted an investigation of the returned device.It was reported that the buttress pin could not lock to the plate.The returned plate was confirmed to have damage to the threads in the va5 hole.Replication of the complaint condition is not possible as the buttress pin was not returned.Dimensional inspection of the va5 hole is not possible due to post manufacturing damage.The drawings were reviewed during investigation.No product design issues or discrepancies were observed that may have contributed to the complaint condition.Based on review of the dhr records there is no indication that any issues with material contributed to the complaint condition.One ncr was noted in the dhr which was not related to the complaint condition.No definitive root cause was able to be determined.When the buttress pin was inserted into the plate, the threads likely deformed.There were no issues during the manufacture of this product that would contribute to this complaint condition.During the investigation, no product design issues or discrepancies were observed that may have contributed to the complaint condition.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|