Model Number ZXT150
Medical Device Problem Code Migration or Expulsion of Device (1395)
Health Effect - Clinical Codes Visual Disturbances (2140); Vitrectomy (2643); No Code Available (3191)
Date of Event 12/12/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).All pertinent information available to abbott medical optics has been submitted.
 
Event or Problem Description
It was reported that a tecnis symfony toric multifocal intraocular lens (model zxt150, +15.5 diopter) was explanted in a secondary procedure because of patient complaining of visual disturbance and was not happy with the results following the lens implant.Reportedly a model zma00 +15.0 diopter intraocular lens was implanted as the replacement lens for the patient.Additional information reports that the lens dislocated post implantation.Reportedly a vitrectomy and limbal relaxing incision were performed during the explant.Patient has dry eye syndrome and was doing well when discharged.No further information was provided.
 
Additional Manufacturer Narrative
Device available for evaluation? yes.Returned to manufacturer on: 02/16/2018.Device returned to manufacturer? yes.Device evaluation: the sample was returned to the manufacturer.Visual inspection was performed and product was cut in half, most probably to make the explant possible.Considering the condition of the returned lens, further analysis is not possible.The reported complaint cannot be confirmed.Manufacturing record review: manufacturing record review of the production order and related document revealed that the product was manufactured and released according to specification.There was no discrepancy found during the review.A search revealed that no similar complaints were received for this production order.Labeling review: the directions for use (dfu) was reviewed.The dfu adequately provides instructions and precautions for the proper use and handling of the product.Conclusion: based on the investigation results there is no indication of a product quality deficiency.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TECNIS SYMFONY TORIC
Common Device Name
MULTIFOCAL IOLS
Manufacturer (Section D)
ABBOTT MEDICAL OPTICS
santa ana CA
MDR Report Key7301428
Report Number9614546-2018-00194
Device Sequence Number1656014
Product Code POE
UDI-Device Identifier05050474605114
UDI-Public(01)05050474605114(17)220420
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
PMA/510(K) Number
P980040
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2018
Reporter Type Manufacturer
Report Source health professional,user faci
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/27/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Expiration Date04/20/2022
Device Model NumberZXT150
Device Catalogue NumberZXT150U155
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/16/2018
Initial Date Received by Manufacturer 01/30/2018
Supplement Date Received by Manufacturer04/06/2018
Initial Report FDA Received Date02/27/2018
Supplement Report FDA Received Date04/27/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age67 YR
-
-