Model Number H7493926028270
Medical Device Problem Code Device Markings/Labelling Problem (2911)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 02/05/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device is a combination product.It is indicated that the device will not be returned for evaluation.If there is any further relevant information obtained, a supplemental medwatch will be filed.(b)(4).
 
Event or Problem Description
Same case as mdr id: 2134265-2018-01404.It was reported that the ro marker band could not be visualized during deployment.The 80% target lesion was located in the mildly tortuous and mildly calcified circumflex artery.Following pre-dilatation, a 2.75 x 28mm synergy ii stent was advanced to treat the lesion.The stent was successfully deployed; however, during deployment, the stent could not be visualized.After that a 2.75 x 38mm synergy ii stent was advanced to treat the left anterior descending artery.The stent was successfully deployed; however, the same issue occurred during deployment.The physician double checked everything and the stent still could not be visualized.A third stent was then deployed without any problems with visualizing and the procedure completed.No patient complications were reported and the patient's status was fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM
Common Device Name
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC - GALWAY
MDR Report Key7303951
Report Number2134265-2018-01403
Device Sequence Number11337788
Product Code NIQ
UDI-Device Identifier08714729840282
UDI-Public08714729840282
Combination Product (Y/N)N
Initial Reporter StateIA
Initial Reporter CountryUS
PMA/510(K) Number
P150003
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/06/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/01/2018
Device Model NumberH7493926028270
Device Catalogue Number39260-2827
Device Lot Number0021370630
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/06/2018
Initial Report FDA Received Date02/28/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age63 YR
-
-