• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COVIDIEN HAWKONE 6FR; CATHETER, PERIPHERAL, ATHERECTOMY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COVIDIEN HAWKONE 6FR; CATHETER, PERIPHERAL, ATHERECTOMY Back to Search Results
Catalog Number H1-M
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 02/08/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
The physician was attempting to use a hawkone directional atherectomy catheter to treat a 20mm severely calcified lesion (90% stenosis) in the proximal right sfa.The vessel had little tortuosity and a 7mm diameter.The device was prepped as per the ifu with no issues identified.The procedure used a 6fr 70cm non-medtronic sheath and a 7mm spider.014¿ filter wire.The vessel was pre-dilated but was not post-dilated.The guidewire was hydrated at preparation.The device was advanced over bifurcation.Severe resistance was experienced during withdrawal and wire wrap around the catheter occurred.This caused the wire to loop during attempted removal of the device from the patient and the device locked up on the wire.The device tip broke off inside the sheath but the device and tip were removed with the sheath.The spider wire remained inside the patient as the only access to vessel.The physician cut the 0.014" spider wire outside the patient to prevent the wire from being pulled out through the groin access site.The physician then attempted to pass a new 10cm 5fr non-medtronic micropuncture sheath over the spider wire into the common femoral artery at the access site but this was unsuccessful.Percutaneous access on opposite groin was successful and a wire, catheter, sheath and snare were used to retrieve the spider filter /wire.Manual pressure was held at the initial groin access site (left), and eventual closure on opposite groin (right) was achieved but the procedure was unable to be completed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HAWKONE 6FR
Common Device Name
CATHETER, PERIPHERAL, ATHERECTOMY
Manufacturer (Section D)
COVIDIEN
9775 toledo way
irvine CA 92618
MDR Report Key7323818
Report Number2183870-2018-00132
Device Sequence Number11164085
Product Code MCW
UDI-Device Identifier00643169728769
UDI-Public00643169728769
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
PMA/510(K) Number
K161361
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/08/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/08/2020
Device Catalogue NumberH1-M
Device Lot NumberA426455
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/08/2018
Initial Report FDA Received Date03/08/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age68 YR
-
-