MAUDE Adverse Event Report: MEDTRONIC, INC COUGAR GUIDE WIRE; WIRE, GUIDE, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC, INC COUGAR GUIDE WIRE; WIRE, GUIDE, CATHETER Back to Search Results
Catalog Number CGRXT190HJ
Medical Device Problem Codes Detachment of Device or Device Component (2907); Device Damaged by Another Device (2915)
Health Effect - Clinical Code Device Embedded In Tissue or Plaque (3165)
Date of Event 02/13/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
The physician implanted an resolute onyx stent in the 1st diagonal.It is reported that the stent had fore- shortening, and that a cougar xt guidewire became entangled in the stent.During the procedure the distal tip of the cougar xt guidewire broke off, with approximately 3 cm of the distal tip remaining in the patient.The wire was trapped in the vessel because it could not be retrieved or snared at that time.No resistance was felt at the time of wire placement, but was going through the entangled stent.The patient was discharged from the hospital in a stable condition.
 
Additional Manufacturer Narrative
Additional information: there were no issues with the stent prior to interaction with the guidewire.No intervention was required for the resolute onyx stent.Received for evaluation was a sprinter legend balloon with the cougar wire caught in the balloon guide wire lumen.Product analysis summary: received for analysis was a cgrxt190hj cougar xt guide wire.The guide wire was received severely stretched and unraveled.On closer visual inspection, the core wire was found to be broken.During analysis of the break, the core wire was noted to be kinked at the exact location of the break.Some of the distal coils remained engaged to the sprinter legend wire lumen.The proximal core wire outer diameter passed measurements.Per specifications: 0.014¿ maximum at joints, along spring, coated core wire, and hypo tube.The whole length of the returned wire is 186.3cm, the tip is missing.Per specification the wire whole length is 190cm, tolerance +2cm ¿1cm.The missing tip approximately accounts for the missing length on the returned guide wire.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Additional information: at the time of the index procedure, the lad presented with a 60% focal stenosis just beyond the takeoff of the first diagonal branch, with mild to moderate diffuse luminal irregularities out to its apex.The d1 had a 90% ostial stenosis.Moderate plaque burden was seen in all coronary artery trees.The physician implanted one resolute onyx stent (2.75 x 15mm) in the 1st diagonal ostium with no issues noted.However plaque shift and abnormal flow reserve was noted towards the lad, suggesting that the lesion just below the first diagonal artery needed treatment.One cougar guide wire was advanced into the 1st diagonal branch, and then over a pressure monitoring guide wire, a resolute onyx 3.5 x 18mm stent was advanced through the previously deployed stent.While trying to position the stent and retract slightly, the stent became entangled in the previous stent in the 1st diagonal branch.It was not possible to retract or advance the undeployed stent.Attempts to release the trapped stent with the aid of the guide catheter were unsuccessful.The stent now appeared fore-shortened on the balloon.It was decided to deploy the stent at its current location at high pressure but the device appeared damaged on review, although the lesion itself was treated well.It was reported that the majority of the stent was right across the ostium on the first diagonal artery, resulting in closure of the first diagonal artery.Some haziness was noted in the ostium of the 1st diag artery and it was noted that the pile up of metal would increase the risk of thrombosis in to the first diagonal artery.There were no issues with the wire prior to the interaction with the stent.The cougar wire was withdrawn from the 1st diag.The physician attempted to advance it through the side of the stent, but as the stent was deformed, it was difficult to access.The cougar was eventually advanced with moderate difficulty.While attempting to advance a 1.5 balloon across the lad the cougar wire fractured.On withdrawal of the wire, approx.3cm of the tip remained in the 1st diag and could not be withdrawn.Attempts to balloon the 1st diag were unsuccessful.After prolonged attempts with multiple wires and non-medtronic catheters, the procedure was terminated as the patient experienced chest pressure and the 1st diag appeared to be completely occluded.The stent in the lad was further post dilated with a 3.5mm non-compliant balloon due to some lucency visible around the stent.This had also been done previously in the procedure.Marked improvement in flow was seen.The patient has been discharged from the hospital in a stable condition.Received for evaluation was a sprinter legend balloon with the wire caught in the balloon guide wire lumen.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Cine image analysis: the returned procedural images capture the patient lesion condition as reported by the account.A guide wire is delivered to the target lesion followed by the successful implantation of the 2.75 x 15 mm resolute onyx stent.A second guide wire is also visible in the adjacent lesion.A subsequent image captures the 3.5 x 18 mm resolute onyx stent implanted adjacent to the first stent in the 1st diagonal ostium.The stent delivery and expansion were not captured in the images provided.Deformation/bunching is visible on the 3.5 x 18 mm resolute onyx stent.Post dilation is performed using an unknown balloon.An image captures what appears to be the sprinter legend device trapped on the cougar guide wire.The moving image captures a tugging motion on the guide catheter and sprinter legend device, which appears to be an attempt to release the device from the guide wire.The cougar wire appears to be stuck in the previously implanted stents.The detached distal portion of the cougar wire is visible in a later image.Attempts to retrieve the detached guide wire were unsuccessful.The last image captured the reported total occlusion of the 1st diagonal branch, the distal section of the cougar guide wire is also visible in the image and remains in the patient.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COUGAR GUIDE WIRE
Common Device Name
WIRE, GUIDE, CATHETER
Manufacturer (Section D)
MEDTRONIC, INC
37a cherry hill dr
danvers MA 01923
MDR Report Key7337191
Report Number1220452-2018-00024
Device Sequence Number1161055
Product Code DQX
UDI-Device Identifier20643169452828
UDI-Public20643169452828
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
K140695
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,consum
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 07/31/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/24/2020
Device Catalogue NumberCGRXT190HJ
Device Lot NumberG17A09007
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/27/2018
Initial Date Received by Manufacturer 02/15/2018
Supplement Date Received by Manufacturer03/21/2018
06/11/2018
07/06/2018
Initial Report FDA Received Date03/14/2018
Supplement Report FDA Received Date04/17/2018
07/04/2018
07/31/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age70 YR
Patient Weight74
-
-