Model Number H7493926016270
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Obstruction/Occlusion (2422)
Date of Event 02/16/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device is a combination product.Device evaluated by mfr.: the complaint device was not received for analysis.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The investigation conclusion is device not returned as the complaint did not include returned device review and lacked the objective evidence or descriptive conditions of the event required to determine what could have contributed to the event.(b)(4).
 
Event or Problem Description
Same case as mdr id: 2134265-2018-01765, 2134265-2018-01766, 2134265-2018-01767, 2134265-2018-01777 and 2134265-2018-01778.It was reported that decreased blood flow occurred.In (b)(6) 2017, the patient presented with st elevation myocardial infarction (stemii).A 2.25 x 28 mm synergy stent and a 2.5016 synergy stent were implanted in the distal right coronary artery (rca).In (b)(6) 2018, the patient presented with an 85-99% stenosed mid rca and a 90% restenosed distal rca.No calcification was noted.A 185 cm str pt²¿ guide wire was introduced.The mid rca was treated with two synergy ii drug-eluting stents, a 2.75 x 16 mm and a 2.75 x 24 mm.The distal rca was treated with a 2.50 x 12 mm synergy ii drug-eluting stent.A 3.0 x 20 mm nc quantum balloon catheter was used for post dilatation.When the physician pulled the pt²¿ guide wire back, the wire caught behind a stent strut and approximately 10 mm of the tip broke off in the distal rca stent.The physician attempted to rewire the vessel so the detached tip could be covered with a stent, but the physician was unable to advance an emerge balloon catheter to the area and the rca began to have a decreased flow.The patient was transferred by an ambulance to another hospital for a cardiac surgeon to evaluate the possibility of performing surgery to remove the detached tip.The detached tip was not removed and was left inside the patient's body.Two saphenous vein grafts (svg) were performed to the rca and the procedure was completed.No further patient complications were reported and the patient's status was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM
Common Device Name
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
MDR Report Key7339487
Report Number2134265-2018-01776
Device Sequence Number16434223
Product Code NIQ
UDI-Device Identifier08714729840107
UDI-Public08714729840107
Combination Product (Y/N)N
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
P150003
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/16/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date11/20/2018
Device Model NumberH7493926016270
Device Catalogue Number39260-1627
Device Lot Number21448269
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/16/2018
Initial Report FDA Received Date03/14/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-