• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ALLERGAN (PRINGY) JUVEDERM VOLUMA WITH LIDOCAINE 1ML; IMPLANT, DERMAL, FOR AESTHETIC USE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALLERGAN (PRINGY) JUVEDERM VOLUMA WITH LIDOCAINE 1ML; IMPLANT, DERMAL, FOR AESTHETIC USE Back to Search Results
Catalog Number 94151EC
Device Problems Fracture (1260); Gel Leak (1267); Improper or Incorrect Procedure or Method (2017)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
Further information regarding event, product, or patient details has been requested.No additional information is available at this time.Device labeling addresses the reported event(s) as follows: method of use-posology juvéderm® voluma¿ with lidocaine is to be used as supplied.Modification or use of the product outside the directions for use may adversely impact the sterility, homogeneity and performance of the product and it can therefore no longer be assured.Remove tip cap by pulling it straight off the syringe as shown in fig.1.Then firmly push the needle provided in the box (fig.2) into the syringe, screwing it gently clockwise.Twist once more until it is fully locked and has the needle cap in the position shown in fig.3.If the needle cap is positioned as shown in fig.4, it is incorrectly attached.Next, remove the protective cap by holding the body of the syringe in one hand, the protective cap in the other, as shown in fig.5, and pulling the two hands in opposite directions.Prior to injecting, depress the plunger rod until the product flows out of the needle.Inject slowly and apply the least amount of pressure necessary.If the needle is blocked, do not increase the pressure on the plunger rod.Instead, stop the injection and replace the needle.Failure to comply with these precautions could cause a disengagement of the needle and/or product leakage at luer-lock level and/or increase the risk of vascular compromise.
 
Event Description
Healthcare professional reported a juvéderm® voluma¿ with lidocaine syringe had a ¿fracture of the syringe in the union with the needle (luer lock).¿ the ¿fracture of the luer lock¿ caused ¿spillage of [the] product.¿ observations indicated a ¿use of incorrect format¿ and an ¿empty syringe.¿ the ¿use of incorrect format¿ was not elaborated.Patient contact was made.No injuries reported.
 
Event Description
Further follow up revealed there was no "use of incorrect format" observed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
JUVEDERM VOLUMA WITH LIDOCAINE 1ML
Type of Device
IMPLANT, DERMAL, FOR AESTHETIC USE
Manufacturer (Section D)
ALLERGAN (PRINGY)
route de promery
zone artisanale de pre-mairy
pringy 74370
FR  74370
MDR Report Key7347174
MDR Text Key102971536
Report Number3005113652-2018-00351
Device Sequence Number1
Product Code LMH
Combination Product (y/n)N
PMA/PMN Number
P110033
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 06/26/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/16/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/30/2019
Device Catalogue Number94151EC
Device Lot NumberVB20A70418
Was Device Available for Evaluation? No
Date Manufacturer Received06/07/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-