| Model Number |
H749CBM3350100 |
| Medical Device Problem Code |
Material Rupture (1546)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
02/21/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Device evaluated by mfr: the device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.(b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a balloon rupture occurred.The target lesion was located in the coronary artery.A 10mm x 3.50mm flextome® cutting balloon® was selected for use.During the procedure, it was noted that the balloon ruptured at 4 atms during inflation.The device was removed over the guidewire and balloon was fully intact.No patient were complications reported and patient's status was fine.
|
| |
|
Additional Manufacturer Narrative
|
|
Device avail.For eval, returned to mfr.On, device returned to mfr., device evaluated by mfr., eval summary attached, method codes, result codes, conclusion codes updated.Device evaluated by manufacturer: the device was returned for analysis.A visual examination identified that the balloon was not folded which indicates that the balloon was subjected to positive pressure.Blood was identified within the balloon and inflation lumen which is evidence of a device leak.The returned device was attached to an encore inflation unit.Positive pressure was applied when liquid was observed to be leaking from a balloon pinhole located approximately at the proximal edge of the proximal markerband.An examination of the balloon material and proximal markerband identified no issues which could potentially have contributed to this complaint.A visual and microscopic examination observed no damage to the tip or blades.All blades were present and fully bonded to the balloon surface.The hypotube was kinked at several locations along its length and the shaft polymer extrusion was also noted to be kinked at approximately 95mm distal of the guidewire port.This type of damage is consistent with excessive force being applied to the delivery system.No other issues were identified during the product analysis.The investigation conclusion is operational context as the product meets the design & manufacture specification but due to anatomical/ procedural factors encountered during the procedure, performance was limited.(b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a balloon rupture occurred.The target lesion was located in the coronary artery.A 10mm x 3.50mm flextome® cutting balloon® was selected for use.During the procedure, it was noted that the balloon ruptured at 4 atms during inflation.The device was removed over the guidewire and balloon was fully intact.No patient were complications reported and patient's status was fine.
|
| |
|