Model Number E2781-28
Medical Device Problem Codes Peeled/Delaminated (1454); Material Deformation (2976)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 03/09/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, during the procedure, the device was used with another instrument, and coag spray was used at 30w.While dissecting mesentery, energy output was distributed from the edge of the shaft, not from the electrode, and mesentery was partially cauterized.The insulation seemed shorter than the electrodes usually used, and the metal element seemed to be exposed more than other devices.There was no patient injury.
 
Additional Manufacturer Narrative
Evaluation summary: one device was received for evaluation.This device had been used in the treatment or diagnosis of a patient.A review of the lot number reported indicates that the product was within the assigned expiration date at the time of the reported incident.The returned product met specification as received.Visual inspection found no defects.The investigation did not identify any defects with the returned electrode.Since the device was used in a procedure, it showed a few minor superficial scratches.The device passed hipot testing.The investigation found the device to function normally and within specifications.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VALLEYLAB
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
COVIDIEN MFG DC BOULDER
5920 longbow dr
boulder CO 80301 3299
MDR Report Key7378987
Report Number1717344-2018-00421
Device Sequence Number1084289
Product Code GEI
UDI-Device Identifier10884524000404
UDI-Public10884524000404
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K964175
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional,u
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/30/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/16/2022
Device Model NumberE2781-28
Device Catalogue NumberE2781-28
Device Lot Number73190223X
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/02/2018
Initial Date Received by Manufacturer 03/12/2018
Supplement Date Received by Manufacturer04/20/2018
Initial Report FDA Received Date03/28/2018
Supplement Report FDA Received Date04/30/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-