Model Number 3295355
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device has not been returned, at this time, to the manufacturer for evaluation.A lot history review (lhr) of rebw2280 showed no other similar product complaint(s) from this lot number.Device has not yet been returned for evaluation.
 
Event or Problem Description
It was reported that a picc line that was removed from patient, appeared to have a crack in the tubing.This picc line was removed and a new one was reinserted.No patient injury reported.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a crack in the tubing was confirmed but the exact cause was unknown.The product returned for evaluation was a 5fr d/l powerpicc solo catheter.The sample had been trimmed at the 22cm depth marking and usage residue was seen throughout.Gross visual evaluation of the sample discovered the presence of a circumferential split in the extension tube of the red-luered lumen.The split was located underneath the luer connector by approximately 2mm.Microscopic examination of the damage showed that the fracture surface was rough and granular and the damage regions correlated to points where the extension tube appeared to be adhered to the luer hub.No damage existed in regions of the extension tube which were not tacked to the luer hub.The fracture features at the damage site appeared similar to fatigue damage and flexural fatigue may have been a contributing factor but the damage location and tacking of the extension tube to the luer wall suggest other, unknown, contributing factor(s) may have also been involved.No further action is required because the reported event could not be related to a deficiency in product manufacture or deficiency while under correct product use.A lot history review (lhr) of rebw2280 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported that a picc line that was removed from patient, appeared to have a crack in the tubing.This picc line was removed and a new one was reinserted.No patient injury reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POWERPICC SOLO CATHETER 5F RADIOLOGY BASIC TRAY (DUAL-LUMEN) (70 CM NITINOL GW)
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7378993
Report Number3006260740-2018-00531
Device Sequence Number11148743
Product Code LJS
UDI-Device Identifier00801741028144
UDI-Public(01)00801741028144
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K072230
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 05/17/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2019
Device Model Number3295355
Device Catalogue Number3295355
Device Lot NumberREBW2280
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/11/2018
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer04/16/2018
Initial Report FDA Received Date03/28/2018
Supplement Report FDA Received Date05/17/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No