MAUDE Adverse Event Report: ALERE SAN DIEGO, INC. ALERE HCG CASSETTE (20MIU/ML) 30T; HCG PREGNANCY TEST

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALERE SAN DIEGO, INC. ALERE HCG CASSETTE (20MIU/ML) 30T; HCG PREGNANCY TEST Back to Search Results
Model Number 92210
Medical Device Problem Code False Negative Result (1225)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 03/01/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation pending.
 
Event or Problem Description
The patient's last menstrual period was (b)(6) 2018.The patient previously received three positive results using first response brand home pregnancy tests.On (b)(6) 2018, the patient was tested at the facility to confirm the results of the home pregnancy tests and presented with symptoms of nausea.A urine sample was collected and produced a negative result at the 3 minute read time using an alere hcg cassette.However, the customer observed a positive result on the alere hcg cassette after 45 minutes.The patient was instructed to follow up with her physician or return for a retest.The customer stated a first-morning sample is typically not used.Troubleshooting was conducted with the customer.The customer was advised that very diluted urine specimens (as indicated by low specific gravity) may not contain representative levels of hcg.Additionally, false negative results may occur when the levels of hcg are below the sensitivity level of the test.When pregnancy is suspected, a first morning urine specimen should be collected 48 hours later and tested.This test provides a presumptive diagnosis for pregnancy.A confirmed pregnancy diagnosis should only be made by a physician after all clinical and laboratory findings have been evaluated.
 
Additional Manufacturer Narrative
Returned product was not received.Retention devices were tested in-house with a qc cut-off hcg standard.All devices showed the correct positive results at the read time and met qc specifications.No false negative results were obtained during in-house testing.Manufacturing batch record review did not uncover any abnormalities.The patients was identified as being in the early stages of pregnancy.The quantity of urine hcg levels may be low.Urine samples are more likely influenced by many factors (such as take in too much water or renal dysfunction) which will dilute the urine sample.Per pi, very dilute urine specimens, as indicated by a low specific gravity, may not contain representative levels of hcg.If pregnancy is still suspected, a first morning urine specimen should be collected 48 hours later and tested.The observation of the test line changing was observed at 45 minutes, which is 42 minutes past the read time.The correct read time for the cassette is 3 minutes; results should not be interpreted past the read time.Based on the information available, there is no indication of a product deficiency and no corrective action is required.(report source) corrected to remove company representative and include consumer.
 
Additional Manufacturer Narrative
Investigation conclusion: returned and retention devices were tested in-house with a qc cut-off hcg standard.All devices showed the correct positive results at the read time and met qc specifications.No false negative results were obtained during in-house testing.The product performed as expected.Manufacturing batch record review did not uncover any abnormalities.The patient was identified as being in the early stages of pregnancy.The quantity of urine hcg levels may be low.Urine samples are more likely influenced by many factors (such as take in too much water or renal dysfunction) which will dilute the urine sample.Per pi, very dilute urine specimens, as indicated by a low specific gravity, may not contain representative levels of hcg.If pregnancy is still suspected, a first morning urine specimen should be collected 48 hours later and tested.The observation of the test line changing was observed at 45 minutes, which is 42 minutes past the read time.The correct read time for the cassette is 3 minutes; results should not be interpreted past the read time.Based on the information available, there is no indication of a product deficiency and no corrective action is required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALERE HCG CASSETTE (20MIU/ML) 30T
Common Device Name
HCG PREGNANCY TEST
Manufacturer (Section D)
ALERE SAN DIEGO, INC.
9975 summers ridge road
san diego CA 92121
MDR Report Key7379567
Report Number2027969-2018-00036
Device Sequence Number11106026
Product Code JHI
UDI-Device Identifier10815845020130
UDI-Public(01)10815845020130(17)190930(10)HCG7090141
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K062361
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,consum
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 03/28/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/30/2019
Device Model Number92210
Device Lot NumberHCG7090141
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/08/2018
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 03/01/2018
Supplement Date Received by Manufacturer04/27/2018
05/14/2018
Initial Report FDA Received Date03/28/2018
Supplement Report FDA Received Date05/02/2018
05/29/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age23 YR
-
-